630577
74
Zoom out
Zoom in
Previous page
1/136
Next page
MPC2500 Operators Manual rev 1.0
64
Chapter 12: Editing a sample
06. Hit the pad to check the end point.
When you hit the pad, the MPC2500 plays the sample. The playback method varies depending on the pad.
If you hit the [PAD 14] (PLAY TO), the MPC2500 will play the sample until the end point.
If you hit the [PAD 15] (PLAY FROM), the MPC2500 will play the sample from the end point.
If you hit the [PAD 16] (PLAY ALL), the MPC2500 will play the whole sample regardless of the start/end point settings.
If you hit any pad from the [PAD 1] to [PAD 12], the MPC2500 will play from the start point to the end point.
Zooming in/out of the waveform
With the Fine window, you can zoom in to a part of the
waveform and edit the part in details. Press the [WIN-
DOW] key in the TRIM page, when the cursor is either
in the St (Start) or End field, and the Fine window will
be displayed.
In the Fine windows, the waveform display varies de-
pending on the location of the cursor. When you select
the St (Start) field with the cursor, it displays the start
point in the center of the window. When you select the
end field, it displays the end point in the center.
If you press the [F2] (ZOOM-) key the waveform will
be zoomed out, if you press the [F3] (ZOOM+) key, it
will be zoomed in.
LINEAR and LOGARITHMIC displays
The vertical axis indicates the sample’s level. Normally,
the waveform display is set to LINEAR, which displays
the sample level as it is. However, some parts (fade out
part etc…) may not be displayed in the waveform if
the level is too low. In this case, you can switch to the
LOG (logarithmic) display by pressing the [F5] (LOG)
key and you can see the parts whose level is low. When
you switch to the LOG mode, the display in the [F5]
key will change to LINEAR. To switch back to the LIN-
EAR mode, press the [F5] key again.
Deleting an unnecessary part
from a sample (DISCARD)
The MPC2500 plays back only the part of the sample from the
start point to the end point. The parts outside these points are
not used for the playback. With the Discard function, you can
delete these unnecessary parts and save the memory space.
01. Adjust the start/end points.
Set the points so that the MPC2500 plays back only
the necessary part.
02. Press the [F6] (EDIT) key.
The Sample Edit window will be displayed.
03. In the Edit field, select DISCARD.
04. Press the [F5] (DO IT) key.
The data outside the start/end points will be de-
leted. The deleted data will be returned to the avail-
able memory.
Deleting a selected range from
sample and moving the data after
the end point towards the start point.
(DELETE)
01. Adjust the start/end points.
Set the range so that you wish to delete with the
start/end point.
02. Press the [F6] (EDIT) key.
The Sample Edit window will be displayed.
03. In the Edit field, select DELETE.
04. Press the [F5] (DO IT) key
The Keep or Retry window will be displayed.
New name field :
Set the name for the new sample
[F2] (PLAY) :
You can audition the new sample.
[F3] (OVER W) : You can delete the original
sample and keep the new
sample by pressing this key.
The sample name remains.
74


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Akai MPC2500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Akai MPC2500 in the language / languages: English as an attachment in your email.

The manual is 12,96 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Akai MPC2500

Akai MPC2500 Quick start guide - English, German, French, Italian, Spanish - 74 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info