AIR 403 Land Manual Document #0049 REV D
SOUTHWEST WINDPOWER 8/20/2001 11
48V AIR 403: Wire Size, Considering 12mph Wind Average and 95% Energy
Transmission Efficiency
# Turbines
0-30ft 31ft-60ft 61ft-90ft 91ft-150ft 151ft-190ft 191ft-250ft 251ft-310ft 311ft-390ft 391ft-500ft
1
14g 14g 14g 14g 12g 10g 10g 10g 8g
2
14g 14g 12g 10g 10g 8g 8g 6g 6g
3
14g 14g 12g 10g 8g 8g 6g 6g 4g
Fuse: 25 Amp Slow-Blow per turbine
Wiring Compensation for Average Wind Speed
For different average wind speeds, the wire LENGTHS in the charts should be
compensated. Compensating by changing wire gauge can lead to safety problems. For the
average wind speed of your site, multiply each wire length
in the chart by the factor shown:
Average Wind Speed Multiplier for Wire LENGTHS
9mph 2
10mph 1.5
11mph 1.25
12mph 1
13mph 0.8
14mph 0.6
Wiring Resistance and Regulation
Wiring resistance can affect the regulation set point of the turbine. Higher wiring resistance
(smaller
wires) will lower the voltage at which the turbine enters regulation and stops
charging. The recommended wiring sizes should provide little effect on the regulation set
point, but all installations should be observed over time to ensure that the batteries are
charged to the proper voltage.
3.1.3 Grounding
Properly grounding the turbine is very important in protecting the electronics for long-term
operation. Grounding procedures must be followed along with any local electrical codes.
IMPORTANT: SEVERE TURBINE DAMAGE CAN RESULT FROM IMPROPER
GROUNDING! FAILURE TO PROPERLY GROUND WILL VOID YOUR WARRANTY.
It is very important to ground your battery bank and ground your tower for lightning and static
protection. Proper grounding also enhances the safety of your turbine system. The green
lead wire provides grounding for the body of the turbine. This wire must be connected to the
system earth ground. This is usually done by connecting a wire from a ground rod near the
base of the tower to the green turbine lead wire. For additional lightning and static
protection, another wire should connect this ground rod to the tower pipe.
The negative wire of your system should also be connected to a ground. This is usually
done by connecting a wire from the negative battery terminal to a nearby ground rod. Wires
with the same ratings as the positive and negative wires must connect all system grounds
(see Wire Size Section 3.1.2).
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Air Marine Air 403 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Air Marine Air 403 in the language / languages: English as an attachment in your email.

The manual is 0,63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info