A300/A300 XT OPERATING MANUAL
© 2002 Design, 2012 Doc. No. 12-7255-r01 (5/14/12)
SET WATER TYPE (TECH only), information includes (Fig. 37):
> Graphic H2O with SET icon.
> Graphic FRESH (or SEA) flashing.
A or M (< 2 sec) to toggle between FRESH and SEA.
S (< 2 sec) to save the setting and access Set Units.
S (2 sec), if the Set Point is not changed, to step back to Set UTL Lead-in.
2 minutes, or M (2 sec), revert to Main.
SET UNITS, information includes (Fig. 38):
> Graphic UNIT with SET icon.
> Graphic IMP with FT icon (or MET with M icon) flashing.
A or M (< 2 sec) to toggle between IMP (imperial) and MET (metric).
S (< 2 sec) to save the setting and access Set Deep Stop (if TECH), or Set Safety Stop (if NORM).
S (2 sec), if the Set Point is not changed, to step back to Set Wet Activation.
2 minutes, or M (2 sec), revert to Main.
SET DEEP STOP (TECH only), information includes (Fig. 39):
> Graphic DEEP with SET, Stop Bar/Arrows, and DS icons.
> Graphic OFF (or ON) flashing.
A or M (< 2 sec) to toggle between OFF and ON.
S (< 2 sec) to save the setting and access Set Safety Stop.
S (2 sec), if the Set Point is not changed, to step back to Set Units.
2 minutes, or M (2 sec), revert to Main.
When Deep Stop is set On, a Stop screen will appear upon ascent to within 10 FT (3 M) below the calculated Stop Depth
which is 1/2 the Max Depth achieved after first having descended to => 80 FT (24 M).
SET SAFETY STOP (NORM), information includes (Fig. 40, 41):
The Safety Stop (SS) can be turned OFF or ON, or set for TMR (Timer) which is a Run Timer that can be Started, Stopped, and
Reset to time an independent SSp at a preferred depth (often required by charter operators).
If while in TECH mode, the SS is set for a Depth and Time other than 15 FT (4.5 M) for 3 minutes, the SS setting will revert to 15
FT (4.5 M) for 3 min if the OP Mode is changed to NORM and a dive is made in NORM.
> Graphic SAFE with SET, Stop Bar/Arrows, and SS icons.
> Graphic OFF, or ON, or ON TMR, flashing.
A (< 2 sec) to step forward through the settings.
M (< 2 sec) to step back through the settings.
S (< 2 sec) to save the setting and access Set Algorithm.
S (2 sec), if the Set Point is not changed, to step back to Set Units.
2 minutes, or M (2 sec), revert to Main.
SET SAFETY STOP (TECH), information includes (Fig. 40, 41, 42):
In TECH mode, the Safety Stop can be turned OFF or ON, set for TMR, or a Stop Depth and Time can be selected.
If the SS is set for a ON while in NORM mode, the SS will remain set ON and revert to the Depth/Time previously set while in
TECH if the OP Mode is changed and a dive is made in TECH.
> Graphic SAFE with SET, Stop Bar/Arrows, and SS icons.
> Graphic OFF, or ON, or ON TMR, flashing.
A (< 2 sec) to step forward through the settings of OFF, ON, ON TMR, and SET.
M (< 2 sec) to step back through the settings.
S (< 2 sec) to save the setting.
2 minutes, or M (2 sec), revert to Main.
. . If OFF, ON, or TMR, is selected, operation will advance to Set Algorithm.
. . If SET is selected, Stop Depth with FT (or M) icon and Stop Time with clock icon will be displayed, with the Time digits
flashing (Fig. 42).
A or M (< 2 sec) to toggle Stop Time between 3:00 and 5:00 (min:sec).
S (< 2 sec) to save the Stop Time setting and flash the Depth digits.
A (< 2 sec) to step through Depth Set Points of 10, 15, and 20 FT (or 3, 4, 5, and 6 M).
M (< 2 sec) to step back through Depth Set Points.
S (< 2 sec) to save Depth setting and revert to the Set SS screen with the graphic SET flashing.
A or M (< 2 sec) to select ON or OFF (or TMR) and advance to Set Algorithm.
S (2 sec), if the Set Point is not changed, to step back to Set Deep Stop.
2 minutes, or M (2 sec), revert to Main.
Fig. 37 - SET WATER TYPE
Fig. 38 - SET UNITS
Fig. 39 - SET DEEP STOP
Fig. 40 - SET SAFETY STOP
(NORM/TECH)
Fig. 41 - SET SAFETY STOP
(NORM/TECH, Timer)
Fig. 42 - SET SAFETY STOP
(TECH, Time/Depth)
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aeris A300 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aeris A300 in the language / languages: English as an attachment in your email.

The manual is 14,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info