A300/A300 XT OPERATING MANUAL
© 2002 Design, 2012 Doc. No. 12-7255-r01 (5/14/12)
SET ALGORITHM, information is to include (Fig. 43):
> Graphic ALGO with SET icon.
> Z+ (or DSAT) icon flashing.
A or M (< 2 sec) to toggle between Z+ and DSAT.
S (< 2 sec) to save the setting and access Set Sampling Rate if NORM, or Set Conservative Factor if TECH.
S (2 sec), if the Set Point is not changed, to step back to Set Safety Stop.
2 minutes, or M (2 sec), revert to Main.
When Z+ is selected, Ni-O2 related calculations are based on the Pelagic Z+ algorithm. When DSAT is selected, the
calculations are based on the standard Pelagic DSAT algorithm.
The selection locks in for 24 hours after surfacing from a NORM, TECH, or FREE (A300) dive.
SET CONSERVATIVE FACTOR (TECH only), information is to include (Fig. 44):
> Graphic CONS with SET and CF icons.
> Graphic OFF (or ON) flashing.
A or M (< 2 sec) to toggle between OFF and ON.
S (< 2 sec) to save the setting and access Set Backlight Duration.
S (2 sec), if the Set Point is not changed, to step back to Set Algorithm.
2 minutes, or M (2 sec), revert to Main.
When the Conservative Factor is set ON, NDLs, which are to be based on the Algorithm selected (DSAT or Z+), are reduced to
the values available at the next higher (+ 3000 feet) Altitude. Ex: NDLs for Sea Level shift to those listed for the 5001 to 6000
foot Altitude range.
SET BACKLIGHT DURATION (TECH only), information is to include (Fig. 45):
Backlight Duration is the time that the Smartglo Backlight remains on after the S button used to activate it is released.
> Graphics GLO and SEC with SET icon.
> Duration Time (seconds) flashing, with clock icon.
A (< 2 sec) to step through the Set Points of 5, 10, and 15 (sec).
M (< 2 sec) to step back through the Set Points.
S (< 2 sec) to save the setting and access Set Sampling Rate.
S (2 sec), if the Set Point is not changed, to step back to Set Conservative Factor.
2 minutes, or M (2 sec), revert to Main.
SET SAMPLING RATE, information is to include (Fig. 46):
Sampling Rate is the frequency (time interval) at which NORM, TECH, GAUG data is sampled and stored in memory for
subsequent download to the PC Interface program.
> Graphics SAMP and SEC with SET icon.
> Time interval (seconds) flashing, with clock icon.
A (< 2 sec) to step through the Set Points of 2, 15, 30, and 60 (sec).
M (< 2 sec) to step back through the Set Points.
S (< 2 sec) to save the setting and revert to SET U.
S (2 sec), if the Set Point is not changed, to step back to Set Backlight Duration.
2 minutes, or M (2 sec), revert to Main.
SET TME (TIME/DATE)
Items set in this group apply to all modes, therefore they remain as set when moving between modes and they can be changed
when in any mode.
SET TME LEAD-IN, information is to include (Fig. 47):
> Graphics Go To TME with SET icon.
S (< 2 sec) to access Set Date Format.
A (< 2 sec) to step forward to Set OP MOD Lead-in.
M (< 2 sec) to step back to Set UTL Lead-in.
2 minutes, or M (2 sec), revert to Main.
Fig. 43 - SET ALGORITHM
Fig. 44 - SET CF
(Conservative Factor)
Fig. 45 - SET BACKLIGHT
DURATION
Fig. 46 - SET SAMPLING
RATE
Fig. 47 - SET TIME LEAD-IN
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aeris A300 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aeris A300 in the language / languages: English as an attachment in your email.

The manual is 14,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info