SET U (UTILITIES) MENU, information includes (Fig. 25A - C):
> Graphics SEt U and MENU,
with the following graphic selections with their last Set Points saved.
> WET ACT ON
Set Points of OFF, ON >> activation of dive mode when wet.
> UNITS IMP
Set Points of IMP (Imperial), MET (Metric) >> Units of Measure.
> DEEP* OFF
Set Points of OFF, ON >> No Deco Deep Stop.
> SAFE* OFF
Set Points of OFF, TMR (Timer), ON >> no deco safety stop.
> ALGO* DSAT
Set Points of DSAT, PZ+ >> Algorithm, basis for Ni-O2 calculations.
> CONSER* OFF
Set Points of OFF, ON >> Conservative Factor, reduces NDLs based on altitude
.
> GLO DUR 15 SEC
Set Points of 5, 10, or 15 SEC >> time Backlight remains on
.
> SAMPLE 60 SEC
Set Points of 2, 15, 30, or 60 SEC >> rate data is recorded for PC download
.
*These items apply to NORM only.
Additional information relating to the effects of the items included are described in associated sections throughout this manual.
A (< 2 sec) to step forward (down) through selections.
M (< 2 sec) to step back (up) through selections.
S (< 2 sec) when the pointer icon is next to a selection will flash that item's Set Point.
• S (2 sec) - to step back from Set U Menu to SET Menu.
A (< 2 sec) to toggle or increase Set Point.
M (< 2 sec) to decrease Set Point.
S (< 2 sec) to save the setting and revert to Set U Menu.
SET SAFETY STOP, information includes (Fig. 26):
The Set U Menu will display the graphic OFF, ON, or TMR solid.
S (< 2 sec) will flash (Fig. 26A) the setting graphic allowing step through of the others with the addition of the SET selection
(Fig. 26B).
OFF >> TMR >> SET >> ON.
S (< 2 sec) while OFF or TMR are flashing will save the setting and revert to the Set U Menu.
S (< 2 sec) while SET is flashing will display the Stop Depth and Time with the Depth setting flashing (Fig. 26C).
A (< 2 sec) to step forward through Depth settings of 10, 15, 20 FT (or 3, 4, 5, 6 M).
M (< 2 sec) to step back through Depth settings.
S (< 2 sec) to save Depth setting and flash Time digits.
A or M (< 2 sec) to toggle Time between 3 and 5 min.
S (< 2 sec) to save Depth/Time setting and revert to the Set U Menu with SET flashing.
A (< 2 sec) to select ON, then S (< 2 sec) to flash ON, then save ON.
SET T (TIME/DATE) MENU, information includes (Fig. 27):
> Graphics SEt t and MENU with Time (clock) icon,
and the following graphic selections with their last Set Points saved.
> DATE FORM M.D
Set Points of M.D (Month.Day), D.M (Day.Month).
> HOUR FORM 12 or 24)
Set Points of 12 (12: A to 11: P), 24 (0: to 23:).
> TIME 10:45 A
Set Points of
12:01 A to 11:59 P, if 12 Hr Format (or 0:01 to 23:59, if 24 Hr Format)
.
> DATE 4.20.11
Set Points >> arranged as M.D.Y (or D.M.Y) by Date Format set.
A (< 2 sec) to step forward (down) through selections.
M (< 2 sec) to step back (up) through selections.
S (< 2 sec) when the pointer icon ( > ) is next a selection will flash that item’s Set Point.
• S (2 sec) - to step back from Set T Menu to SET Menu.
A (< 2 sec) to increase Set Points one at a time.
A (hold) to increase Set Points at a rate of 8 per second.
M (< 2 sec) to decrease Set Points one at a time.
S (< 2 sec) to save the setting which becomes solid, then the next value flashes.
> The left digits of the Time and Date selections will flash first allowing them to be changed after which the next digits (to the
right) flash allowing them to be changed.
> TIME (hr:min) >> Hour digits flash, then Minutes.
> DATE (m.d.y or d.m.y) >> Year digits flash, then Month, then Day, regardless of their position.
Fig. 25B - SET SAMPLING
(sample of changing a setting)
Fig. 25A - SET U MENU
(stepping through)
Fig. 26A - SET SAFETY
STOP
Fig. 26C - SET SS
(Depth, Time)
Fig. 26B - SET SS
(to access Set Depth/Time)
Fig. 27 - SET T MENU
(stepping through)
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aeris A300 AI at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aeris A300 AI in the language / languages: English as an attachment in your email.

The manual is 11,42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info