A300 AI OPERATING MANUAL
© 2002 Design, 2011 Doc. No. 12-7265-r01 (12/28/11)
FO2 50% Default -
> When the Default is set OFF, FO2 values will remain set at their last settings saved until 24 hours elapse without conducting
a dive.
> When the Default is set ON and FO2 is set for Nitrox, 10 minutes on the surface after that dive the FO2 will be displayed
as 50 and further dives will be calculated based on 50% O2 for oxygen calculations and 21% O2 for Nitrogen calculations
(79% Nitrogen), unless FO2 is set before the dive.
> FO2 will continue to reset to the Default after repetitive dives until 24 hours elapse with no dive, or the Default is set OFF.
SET F (FO2) MENU, information includes (Fig. 22):
> Graphics SEt and MENU,
with the following graphic selections with their last Set Points saved.
> GAS1 AIR
Set Points of AIR, 21 to 100%, increments of 1%
.
> GAS2 32%
Set Points of OFF, AIR, 21 to 100%, increments of 1%
.
> GAS3 80%
Set Points of OFF, AIR, 21 to 100%, increments of 1%
.
> GAS4 OFF
Set Points of OFF, AIR, 21 to 100%, increments of 1%
.
> DEFAULT ON
Set Points of OFF, ON
.
When Gas 2 is OFF, Gas 3 & 4 remain OFF, and when Gas 3 is OFF Gas 4 will remain OFF. This blocks access to the Gas
Switch screens for gasses not selected for use.
During the time that numeric FO2 values (21 to 100) are flashing, the MOD (Max Operating Depth) allowed for the PO2
alarm set will be displayed in place of the graphic SEt, and the PO2 alarm value set will be displayed in place of the
graphic MENU.
• S (< 2 sec) - to access Set F Menu while the selection Arrow icon ( > ) is next to Set F on the NORM Menu.
• A (< 2 sec) - to step down (forward) through selections.
• M (< 2 sec) - to step up (back) through selections.
• S (< 2 sec) - to access selection indicated by Arrow icon ( > ).
This causes the FO2 setting to flash allowing it to be set.
• S (2 sec) - to step back from Set F Menu to SET Menu.
SET FO2 & PO2 ALARMS:
A (press/hold), while the FO2 digits are flashing (Fig. 23A) - to scroll upward through the Set Points from Air to 21 through
100 in 1% increments, at a rate of 8 per second.
The scroll will stop when the button is released, or momentarily at 32, then 50, then 80 (%).
A (< 2 sec) - to step upward through FO2 Set Points one at a time.
M (< 2 sec) - to step back through FO2 Set Points one at a time.
S (< 2 sec) - save the FO2 setting, and flash the PO2 digits if Nitrox (Fig. 23B), or revert to SURF MAIN if Air.
A (< 2 sec) - to step upward through PO2 Alarm Set Points from 1.00 to 1.60 (ATA) in .05 increments.
M (< 2 sec) - to step back through PO2 Set Points.
S (< 2 sec) - to save the PO2 setting and access Set Gas 2.
S (2 sec) - to revert to Set F Menu displaying the settings.
M (2 sec) or if no button is pressed during a 2 minute period - to revert to SURF MAIN.
Once any Gas is set for Nitrox, any other Gas set for Air will automatically be set to 21%.
SET FO2 50% DEFAULT, information includes (Fig. 23C):
> Graphics DEFAULT and 50.
> Set Point graphic OFF (or ON), flashing.
> Nx icon.
• A or M (< 2 sec) - to toggle between OFF and ON.
• S (< 2 sec) - to save the setting and revert to Set F.
SET A (ALARMS) MENU, information includes (Fig. 24A/B):
> Graphics SEt A and MENU,
with the following graphic selections with their last Set Points saved.
> AUD ON
Set Points of OFF, ON >> Audible.
> DEPTH 140 FT
Set Points of OFF, 30 to 330 FT (or 10 to 100 M), increments of 10 FT (3 M).
> EDT 60 MIN
Set Points of OFF, 10 to 180 MIN, increments of 5 MIN >> Elapsed Dive Time.
> TLBG* 4 BAR
Set Points of 1 to 4 BAR, increments of 1 BAR >> Tissue Loading Bar Graph.
> DTR* 5 MIN
Set Points of OFF, 1 to 20 MIN, increments of 1 MIN >> Dive Time Remaining.
> TURN 1400 PSI
Set Points of OFF, 1000 to 3000 PSI (or 70 to 205 BAR), increments of 250 PSI (5 BAR).
> END 500 PSI
Set Points of 300 to 1500 PSI (or 20 to 105 BAR), increments of 100 PSI (5 BAR).
*These items apply to NORM only.
A (< 2 sec) to toggle or increase Set Point.
A (hold) to increase Set Point at a rate of 8 per second.
M (< 2 sec) to decrease Set Point.
S (< 2 sec) to save the setting and revert to the Set A Menu.
• S (2 sec) - to step back from Set A Menu to SET Menu.
Fig. 22 - SET F MENU
(stepping through)
Fig. 23A - SET FO2
(changing the setting)
Fig. 23B - SET PO2 ALARM
(after FO2 setting is saved)
Fig. 23C - SET FO2 50%
DEFAULT
Fig. 24A - SET A MENU
(stepping through)
Fig. 24B - SET END ALARM
(sample of changing a setting)
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aeris A300 AI at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aeris A300 AI in the language / languages: English as an attachment in your email.

The manual is 11,42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info