A100 OPERATING MANUAL
© 2002 Design, 2012 Doc. No. 12-7271-r01 (4/25/12)
SET ALM (ALARMS) LEAD-IN, information includes (Fig. 25):
> Graphics Go To and ALM with SET icon.
B (2 sec) to access Set Depth Alarm.
B (< 2 sec) to step forward to Set UTL Lead-in.
2 minutes, revert to Main if B is not pressed.
SET DEPTH ALARM, information includes (Fig. 26):
This feature is not the same as the Delayed Violation depth alarm described later.
> SET icon.
> Graphic OFF (or ON) flashing, with Depth value last set with FT (or M) and MAX icons solid.
B (< 2 sec) to step forward through the selections OFF, ON, and SET.
B (2 sec) to save the selection and access Set EDT Alarm if OFF or ON is saved, or flash the Depth digits if SET is saved.
If SET is saved and the Depth digits are flashing >>
B (< 2 sec, repeatedly) to step upward through the Set Points from 30 to 330 FT (10 to 100 M) in 10 FT (1 M)
increments.
B (2 sec) to save the Depth value (solid) and flash the graphic SET, allowing ON or OFF to be selected.
SET EDT ALARM, information includes (Fig. 27):
> SET icon.
> Graphic OFF (or ON) flashing, with Time value (hr:min) last set with wave/clock icon solid.
B (< 2 sec) to step through the selections OFF, ON, and SET.
B (2 sec) to save the selection and access Set DTR Alarm if OFF or ON is saved, or flash the Time digits if SET is saved.
If SET is saved and the Time digits are flashing >>
B (< 2 sec, repeatedly) to step upward through Set Points from 0:10 to 3:00 (hr:min) in :05 increments .
B (2 sec) to save the Time value (solid) and flash the graphic SET, allowing ON or OFF to be selected.
SET DTR ALARM, information includes (Fig. 28):
> SET icon.
> Graphic OFF (or ON) flashing, with Time value (hr:min) last set with wave/clock/profile icon solid.
B (< 2 sec) to step through the selections OFF, ON, and SET.
B (2 sec) to save the selection and revert to Set ALM if OFF or ON is saved, or flash the Time digits if SET is saved.
If SET is saved and the Time digits are flashing >>
B (< 2 sec, repeatedly) to step upward through Set Points from 0:05 to 0:20 (hr:min) in :01 increments.
B (2 sec) to save the Time value (solid) and flash the graphic SET, allowing ON or OFF to be selected.
SET UTL (UTILITIES) LEAD-IN, information includes (Fig. 29):
> Graphics Go To UTL with SET icon.
B (2 sec) to access Set Units.
B (< 2 sec) to step forward to ID - SN.
2 minutes, revert to Main if B is not pressed.
SET UNITS, information includes (Fig. 30):
> Graphic UNIT with SET icon.
> Graphic IMP with FT icon (or MET with M icon) flashing.
B (< 2 sec) to toggle between IMP (imperial) and MET (metric).
B (2 sec) to save the setting and access Set Algorithm.
SET ALGORITHM, information is to include (Fig. 31):
> Graphic ALGO with SET icon.
> Z+ (or DSAT) icon flashing.
B (< 2 sec) to toggle between Z+ and DSAT.
B (2 sec) to save the setting and access Set Conservative Factor.
When Z+ is selected, Ni-O2 related calculations are based on the Pelagic Z+ algorithm. When DSAT is selected, the
calculations are based on the standard Pelagic DSAT algorithm.
The selection locks in for 24 hours after surfacing from a dive.
Fig. 25 - SET ALARMS
LEAD-IN
Fig. 26 - SET DEPTH ALARM
Fig. 27 - SET EDT ALARM
Fig. 28 - SET DTR ALARM
Fig. 29 - SET UTILITIES
LEAD-IN
Fig. 30 - SET UNITS
Fig. 31 - SET ALGORITHM
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aeris A100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aeris A100 in the language / languages: English as an attachment in your email.

The manual is 7,69 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info