618063
11
Zoom out
Zoom in
Previous page
1/32
Next page
11
A100 OPERATING MANUAL
© 2002 Design, 2012 Doc. No. 12-7271-r01 (4/25/12)
Log Data 1, information includes (Fig. 20):
> Z+ (or DSAT), CF, NX icons, if they apply.
> Max Depth with FT (or M) and MAX icons.
> Elapsed Dive Time (hr:min) with wave/clock (EDT) icon.
> TLBG with max segment flashing, others fixed up to end of dive accumulation. Blank if VGM.
> VARI, max Ascent Rate sustained for 4 sec.
> LOG icon.
B (< 2 sec) to access that dive's Log Data 2 screen if Nitrox, or revert to Preview if not.
B (2 sec) to revert to Log Lead-in.
Log Data 2 (only if Nitrox), information includes (Fig. 21):
> O2% with icon, at end of dive.
> FO2 value set with icon.
> Max level of PO2 achieved with icon.
> NX and LOG icons.
B (< 2 sec) to access the previous dive's Preview screen.
B (2 sec) to revert to Log Lead-in.
SETTING FO2
FO2 can be set for Air, and 21 to 50% Nitrox. The PO2 Alarm is fixed at 1.40 with a Warning fixed at 1.20.
There is no FO2 50% Default setting like previous AERIS Nitrox dive computers.
FO2 set for Air:
The default FO2 each new period of activation is AIR.
When FO2 is set for AIR -
. . calculations are the same as when it is set for 21% O2.
. . it remains set for AIR until it is set for a numerical value (21 to 50%).
. . O2% and PO2 values and/or warnings will not be displayed at any time, on the surface or during dives.
. . max depths allowed by the PO2 limit set will not be displayed in Plan.
Internally, the unit will keep track of the oxygen loading so that if FO2 is later set for a numerical value of FO2, the oxygen accu-
mulated during previous Air dives will be accounted for in the next Nitrox dive (during that series of repetitive dives).
FO2 set for Nitrox:
When FO2 is set for a numerical value (21 to 50%), the dive is considered Nitrox with the NX icon displayed on all applicable
screens.
Once a dive is conducted with FO2 set for Nitrox, the Air option will be disabled until 24 hours elapse after the last dive. The
Air option will not be displayed in Set FO2 until a full 24 hour Surface Interval has elapsed.
SET GAS (FO2) LEAD-IN, information includes (Fig. 22):
> Graphics Go To GAS with SET icon.
B (2 sec) to access Set Gas 1.
B (< 2 sec) to step forward to Set ALM Lead-in.
2 minutes, revert to Main if B is not pressed.
SET GAS, information includes (Fig. 23, 24):
> SET, FO2 icons.
> CF, Z+ (or DSAT) icons, if they apply.
> Graphic AIR flashing, or -
. . Max Depth allowed with FT (or M) and MAX icons.
. . FO2 (numeric) value flashing
.
. . PO2 Alarm value with PO2 icon.
Fixed at 1.40 (no setting).
B (< 2 sec repeatedly) to step upward through the Set Points from Air to 21 through 50% in 1% increments.
B (2 sec) to save the setting and revert to Set Gas Lead-in.
Fig. 20 - LOG DATA 1
Fig. 21 - LOG DATA 2
Fig. 22 - SET GAS LEAD-IN
Fig. 23 - SET GAS
(for Air)
Fig. 24 - SET GAS
(for Nitrox)
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aeris A100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aeris A100 in the language / languages: English as an attachment in your email.

The manual is 7,69 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info