A100 OPERATING MANUAL
© 2002 Design, 2012 Doc. No. 12-7271-r01 (4/25/12)
PLAN MODE
No Deco time Limits (NDLs) and O2 time Limits (OTLs) in Plan Mode are based on the Algorithm selected (DSAT or Z+), the FO2
(Gas) set, and residual nitrogen (or O2) remaining from previous dives.
PDPS (Pre Dive Planning Sequence)
Plan screens will sequence through Depths from 30 to 190 FT (9 to 57 M), or the Max Depth that will allow theoretical No Deco
Dive Time of at least 1 minute based upon the previous dive profiles in a series of repetitive dives and taking into account descent
and ascent rates of 60 FPM (18 MPM).
When the Conservative Factor is set On, NDLs are reduced to the values of the next 3,000 foot (915 meter) higher Altitude.
Refer to tables in back.
Plan Lead-in, information includes (Fig. 14, 15):
> Z+ (or DSAT), CF, NX icons, if they apply.
> Graphic PLAN if Air, or -
Max Depth allowed for FO2 setting with FT (or M) and MAX icons if Nitrox.
> Graphic AIR with FO2 icon, or -
FO2 set (xx%) with FO2 icon, and PO2 alarm setting (fixed at 1.40) with PO2 icon if Nitrox.
> Plan mode icon (wave/clock/profile).
• B (2 sec) to access PDPS.
• B (< 2 sec) to step forward to Log Lead-in.
PDPS, information includes (Fig. 16, 17):
> Z+ (or DSAT), CF, NX icons, if they apply.
> Plan Depth value with FT (or M) icon.
> FO2 set (xx%) with FO2 icon if Nitrox, blank if Air.
> NDC (No Deco) or O2 limit (hr:min) with mode icon (wave/clock/profile), with O2 if OTL.
> Plan mode icon (wave/clock/profile).
• B (< 2 sec), repeatedly, to step through screens one at a time from 30 to 190 FT (9 to 57 M) in increments of 10 FT (3 M),
then repeat the step through.
• B (2 sec), at any time, to exit the PDPS and revert to the Plan Lead-in screen.
LOG MODE
Information from the latest 12 dives is stored for viewing. After exceeding 12 dives, the most recent dive is stored while the old-
est is deleted.
> Dives are numbered from 1 to 12 starting each time the unit is activated. After 24 hours elapse with no dive, the first dive of
the next period of operation is #1.
> 10 minutes after a dive, the Log screens for all dives stored can be viewed.
If a dive’s elapsed time (EDT) exceeds 9:59 (hr:min), data at the 9:59 interval is recorded in the Log upon surfacing of the unit.
Log sequence = Lead-in > Preview > Data 1 > Data 2.
Log Lead-in, information includes (Fig. 18):
> Graphics Go To LOG.
B (2 sec) to access the Log Preview screen, of the most recent dive recorded.
B (< 2 sec) to step forward to Set Lead-in.
2 minutes, revert to Main if B is not pressed.
Log Preview, information includes (Fig. 19):
> Graphics NONE and YET if no dive recorded yet, or -
pre dive Surface Interval (hr:min) with clock/wave icon, - : - - if # 1 (no previous dive that period), and -
graphic SEA (or L2 - L7), altitude level of dive.
> Dive number (1 to 12) with # icon.
> NX icon, if it applies.
> LOG icon.
B (< 2 sec) to access that dive's Log Data 1 screen.
B (2 sec) to revert to Log Lead-in.
Fig. 18 - LOG LEAD-IN
Fig. 19 - LOG PREVIEW
Fig. 14 - PLAN LEAD-IN
(Gas set for Air)
Fig. 15 - PLAN LEAD-IN
(Gas set for Nitrox)
Fig. 16 - PDPS
(Gas set for Air)
Fig. 17 - PDPS
(Gas set for Nitrox)
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aeris A100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aeris A100 in the language / languages: English as an attachment in your email.

The manual is 7,69 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info