For the Fitter
Floors
The standing surface of the unit must be level and sufficiently stable so that the housing is not
deformed.
A temperature resistance of the fastening wall of at least 85 °C and of the floor of at least 80 °C
must be ensured. The heaters can be placed on any conventional floor but changes may occur in
the rail area on PVC, parquet and long pile carpeted floors under the influence of pressure and
temperature. In this case heat-resistant underlay tiles must be used (to be provided on site).
2.4.2 Fastening of the Units with Floor Clearance with Wall Consoles
Before installing the unit, two wall holders (26) must be screwed to the wall under consideration
of the safety distances (dimensions see ”Technical data” page 9).
The following must be observed with this installation site:
If a stable wall is available, the unit can be fixed to the installation wall with the wall holders
provided.
The following applies:
WSP 1210 F to WSP 3610 F = Floor clearance only possible with wall holder;
WSP 4210 F and WSP 4810 F = Floor clearance only possible in connection with the wall holder
with a support console.
Attention:
It should be checked thoroughly whether the fastening wall and the enclosed screws and plugs
are suitable to take the full weight of the unit.
With a wall of limited stability, floor clearance for the units WSP 1210 F to WSP 3610 F is only
possible in connection with the combination wall holder/support console (special accessories).
2.4.3 Installation with Floor Consoles
If no suitable fastening wall exists, the unit must be fixed to the floor with the floor console
(special accessory) (screw fitting unit/console and console/floor).
2.5 Unit Installation (fig. 3-14)
Before fixing the unit, make sure that the permissible minimum distances from adjacent objects
are kept.
Two wall holders are fixed to the back wall of the unit which must be unscrewed before installa-
tion.
2.5.1 Unit Installation (fig. 3-6)
Unscrew the air outlet grille (5) and remove with the air inlet grille;
Unscrew the front wall (4) at the bottom edge, swing forward and remove by lifting slightly at
the top edge;
Unscrew the inside front wall (8) at the side lugs, swing the top end forward and pull out from
above;
Lift the right side wall (3) slightly and remove;
Feed the power cables and connecting cables for charging control unit and discharge control
unit through the opening in unit rear wall (15) and connect according to section 2.5.2 (lay
connecting cable about 210 mm and shorten as required so that it does not obstruct the air
vents in the side wall);
Install the unit according to section 2.4;
Remove cover plate (10), cardboard inlays and operating button and mounting material kit
(screws and plugs) from inside (fig. 9). This must be completely free of foreign bodies such as
packing leftovers.
Check the thermal insulation in the unit for transportation damage and replace if necessary.
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AEG WSP 3610 F at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AEG WSP 3610 F in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 2,29 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info