3/N/PE ~ 50 Hz 400 V
L2L3123
91,6 % P
Nenn
L2L3N
L1
N
L1
X1
3/N/PE ~ 50 Hz 400 V
1
L2L3123
100 % P
Nenn
(Serienverdrahtung)
L2L3
3
L1
L1
X1
3/N/PE ~ 50 Hz 400 V
L2L3123
83,3 % P
Nenn
L2L3N
8 h 9 h 10 h
Power adaptation according to rated charging time
By moving or removing bridges at the terminals, the output can be adapted to the rated charging
time specified by the electricity supply company.
Unit rating plate
Observe the labelling on the rating plate and the circuit diagram!
After connecting electrically, the box corresponding to the connection rating and rated charging
time of the unit on the rating plate and the circuit diagram in these installation instructions
should be marked with a smear-proof ballpoint pen.
2.5.3 Unit Ready for Operation
Cleaning the unit (fig. 13 and 14)
The open unit must be cleaned after installation and insertion of the storage blocks.
The fans and the air guidance assembly must be removed for this.
Unscrew and remove the air guidance assembly (16).
Lift and remove the fan (18) after loosening (not removing) the screws at the front of the
support brackets (pay attention to cable laying!).
In some units, the discharge temperature control unit (19) including support plate must be
unscrewed.
Make sure the wires are not damaged when setting down the removed parts.
Clean the floor plate and fan (avoid damage to lamellas!). Then re-install the fans, possibly the
temperature limiter and the air guidance module (correct cable laying!).
Close the unit (fig. 15 and 16)
Place the inside front wall including thermal insulation with the side edging on the supports at
the bottom, press the unit on top and screw together
(in the WSP 4210 F and WSP 4810 F, another screw must be screwed in the middle);
Hang in the right side wall at the bottom, tilt up, hang in at top and fix with screw; (reverse
order see 2.5.1 – disassembly right side wall fig. 6)
Hang in front wall at top, swing to the heater at the bottom and fix with 2 screws (always use
the two inside threaded holes) (fig. 15);
Screw on the air outlet grille, screwing the screws hand tight and then back about 1 turn
(fig. 16);
Place the air inlet grille at an angle on the lugs in the heater base, swing round at the top and
snap in behind the air outlet grille (fig. 16).
For the Fitter
Heating element model
Rated charging time
Connection variants (kW)
Model
WSP 1210 F
WSP 1810 F
WSP 2410 F
WSP 3010 F
WSP 3610 F
WSP 4210 F
WSP 4810 F
8h
1.2
1.8
2.4
3.0
3.6
4.2
4.8
8h
9h
1.1
1.65
2.2
2.75
3.3
3.85
4.4
10h
1.0
1.5
2.0
2.5
3.0
3.5
4.0
83.3 % P
rated
91.6 % P
rated
100 % P
rated
(series wiring)
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AEG WSP 3610 F at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AEG WSP 3610 F in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 2,29 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info