2.2 Technical Description (page 3, fig. 1)
1 Control panel
2 Cover
3 Right side wall
4 Front wall
5 Air outlet grille
6 Air inlet grille
7 Inside front wall
8 Storage blocks
9 Cover plate
10 Thermal insulation
11 Floor thermal insulation
12 Mixing air flap
13 Air duct
14 Cable duct
15 Heating element
17 Safety temperature regulator - charging (N4)
18 Safety temperature limiter (F1)
19 Wall holder
A1 Electronic charging control unit (page 12)
V4 Operating and fault indicator
X16 Control signal adapter 4-stage
X17 4-stage charging factor reducer
2.2.1 Function Principle
The storage blocks are heated up by the heating elements between the rows of storage blocks.
Charging is set continuously with the charging control unit (selector knob fig. 16)
Start and duration of the charging time are determined by the responsible electricity supply
company.
A built-in safety temperature controller (17) and a safety temperature limiter (18) prevent
overheating of the unit. Whilst the safety temperature regulators switch on again automatically,
the safety temperature limiter must be switched back on by the technician by pressing in the knob
in the middle of the limiter after eliminating the cause of the error.
The heat stored in this way is then re-discharged through surface of the unit by natural
convection, radiation and heat conduction.
2.2.2 Electronic Charging Control Unit
Behaviour in case of fault
The charging control unit in the heater is set at the factory to ”positive fault behaviour (80 % PS),
i.e. in the case of a defective charging control unit (e.g. failure of the control signal), the unit is
fully charged.
The unit can be switched to ”negative fault behaviour” (no charging of the storage heater) by
moving the plug-in bridge X16 to position ”80 % NS” when the device is connected to a digital
charging control unit.
Operation with the charging control unit
The appropriate notes in the operating and installation instructions of the charging control unit
must be observed.
Control signal
The electronic charging control unit can be connected to different control signals (ED) of control
units and can therefore be integrated in existing systems.
It is factory set to an AC control signal (AC voltage signal at terminals A1/A2) with 80 % ED.
Other ED signals (68/72, 37/40 %) can be selected by moving the plug-in bridge X16. This is
necessary when the unit is integrated in an already existing system which controls the charging
with one of the named ED signals.
For the Fitter
03 GB WSP_1510S.p65 27.01.2004, 16:3227
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AEG WSP 1510 S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AEG WSP 1510 S in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 2,06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info