648419
16
Zoom out
Zoom in
Previous page
1/48
Next page
16
Installation - for contractors
Temperature setback via control cable
To reduce the temperature set at the thermostat (by
3.5 °C), the black control cable is activated via an exter-
nal electronic contact (e.g. a time switch).
Control cable connected to a control unit
You can connect the appliance to any control unit that
issues the following waveforms as control signals:
Command Oscilloscope Operating
mode
Heating temper-
ature
No power Comfort
mode
Subject to the set-
ting of the tempera-
ture control knob
Complete oscil-
lation 230 V
Setback
mode
Approx. 3.5 °C
lower than the tem-
perature set on the
temperature control
knob
Semi-oscillation
negative -230 V
Frost pro-
tection
Frost protection
temperature (ap-
prox. 6 °C)
Semi-oscillation
positive +230 V
Appliance
OFF
None
10. Commissioning
10.1 Initial start-up
When the appliance is rst started up, it may give off a
smell. Make sure that the room is adequately ventilated
(with a partially open window, for example).
10.2 Appliance handover
» Explain the functions of the appliance to the user.
» In particular, draw attention to the safety instructions.
» Hand over the operating and installation instructions
to the user.
11. Shutdown
» Move the sliding switch to the "appliance off"
position.
12. Troubleshooting
Note
The power cable may only be replaced by a qualied
contractor using original spare parts supplied by us.
13. Specication
13.1 Dimensions and connections
a20
i13
250
11
8
100
b01
D0000047391
KLE 502 KLE 1002
a20 Appliance Width mm 665 1110
b01 Power connection Entry electrical cables
i13 Wall mounting bracket Horizontal hole spacing mm 210 654
13.2 Data table
KLE 502 KLE 1002
189771 189772
Electrical data
Power supply 1/N ~ 230/240 V 1/N ~ 230/240 V
Connected load kW 0.5 1
Dimensions
Height mm 250 250
Depth mm 100 100
Width mm 662 1110
Weights
Weight kg 4 5.9
Versions
Colour White, RAL 9016 White, RAL
9016
Frost protection setting °C 7 7
IP rating IP24 IP24
Safety category II II
Values
Setting range °C 10-30 10-30
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AEG KLE 502 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AEG KLE 502 in the language / languages: English, German, Dutch, French, Polish as an attachment in your email.

The manual is 8,8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info