Installation – for qualied contractors
INSTALLATION
7. Safety
Only a qualied contractor should carry out installation,
commissioning, maintenance and repair of the appliance.
7.1 General safety instructions
We guarantee trouble-free function and operational relia-
bility only if original accessories and spare parts intended
for the appliance are used.
!
Material losses
Observe the maximum inlet temperature. Higher
temperatures may damage the appliance. You can
limit the maximum inlet temperature by installing a
central thermostatic valve.
7.2 Instructions, standards and regulations
Note
Observe all applicable national and regional regula-
tions and instructions.
The protection rating IP 25 (hoseproof) can only be
ensured with a correctly tted cable grommet.
The specic electrical resistance of the water must
not fall below that stated on the type plate. In a linked
water network, factor in the lowest electrical resist-
ance of the water (see chapter "Installation / Spec-
ication / Data table"). Your water supply utility will
advise you of the specic electrical water resistance
or conductivity.
8. Appliance description
8.1 Standard delivery
The following are delivered with the appliance:
Wall mounting bracket
Threaded studs, screws and rawl plugs for the wall
mounting bracket
Installation template
2 twin connectors (cold water with shut-off valve)
Flat gaskets
Cable grommet (power cable from above / below)
Screws / rawl plugs for xing the back panel in the
case of water connection on nished walls
Additional ow limiter in the cold water pipe (only
DDLE Basis 18/21/24)
8.2 Accessories
Tap
ADEo 70 WD Mono lever mixer tap with bath / shower
changeover
Stove connection set
Connection set for the power connection of the
DDLE Basis 11 and DDLE Basis 13
Installation accessories
Pipe assembly, undersink installation UT 104, connec-
tions: Finished walls, G 3/8, top. Water connections with
12 mm compression tting.
Universal mounting frame
Mounting frame with electrical connections.
Pipe assembly for undersink appliances
You will need the undersink installation set if you use the
water connections (G 3/8 A) at the top of the appliance.
Pipe assembly for offset installation
You will need the pipe assembly with bends if you intend
to offset the appliance by 90 mm downwards from the
water connection.
Pipe assembly for replacing a gas water heater
You will need the pipe assembly if you are using the exist-
ing gas water heater connections (cold water connection
on the left-hand side DHW connection on the right-hand
side).
Load shedding relay (LR 1-A)
The load shedding relay for installation in the distribution
board provides priority control for the instantaneous water
heater when other appliances, such as electric storage
heaters, are being operated simultaneously.
ZTA 3/4 – Central thermostatic valve
The thermostatic valve is for central premixing, for exam-
ple on an instantaneous water heater with solar thermal
system.
9. Preparations
9.1 Installation site
!
Material losses
Install the appliance in a room free from the risk of
frost.
» Always install the appliance vertically and near the
draw-off point.
The appliance is suitable for undersink and oversink in-
stallations.
Undersink installation
26_02_02_1345
1
2
1 Cold water Inlet
2 DHW outlet
Oversink installation
12
26_02_02_1344
1 Cold water Inlet
2 DHW outlet
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AEG DDLE Basis 13 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AEG DDLE Basis 13 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 19,49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info