Surrounding aperture
The insert is constructed in a way that makes it possible to make the brickwork shut almost tight around the insert
the first 10 cm in the depth from the front. This means that the hole in the front brickwork must be 54-55 cm high
and 58.5-59 cm wide. After the first 10 cm in the depth there must be 2.5 cm air space around the insert which
gives a minimum total width of 63.5 cm. and a total depth of minimum 49 cm in the hole. It is very important to
ensure the 2.5 cm air space around the insert and that the installation is correct (see point 2.2); otherwise the
fireplace insert will not cool down sufficiently. A correct cooling is crucial for the energy efficiency as well as for the
function of the Aduro-tronic.
The front of the insert with the frame covers an area of 57.4 cm in height and 63.5 cm in width.
When making the whole in the brickwork then please also remember that you might need some extra space when
the pipe has to be mounted.
2.1 Position of the fireplace insert/distance requirements
The new fireplace insert must be installed in a suitable and physically possible position. You need to be sure that
the position complies with local regulations. Distance requirements will only apply if the fireplace insert is to be
placed close to flammable materials. See below.
Distance to flammable material
Behind the fireplace
insert
To the sides of the
fireplace insert
To furniture
Minimum height
above floor level
25 cm
30 cm
110 cm
26 cm
It is possible to reduce the distance to flammable material by insulating with at least 5.0 cm insulation with identical
properties to Aduro Superisol, Isolrath 1000 or similar material around the Aduro 5-1. Please make very sure that
there is still at least a 2.5 cm space around the Aduro 5-1. This means that the distance to flammable material can
be reduced to 7.5 cm (2.5 cm space around the insert + 5 cm insulation).
Behind stove
25
110
3030
Fjeder til selvluk
Askeskuffe og opstarts-/
primærspjæld
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aduro 5-1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aduro 5-1 in the language / languages: English, German, Danish as an attachment in your email.

The manual is 1,33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info