Appendix IV – Wiring Information
95
1.11 Infrared motion detectors
Infrared motion sensors detect the infrared heat
movement of living creatures and must only be
used indoors. For transparency reasons, avoid
using motion sensors with door/window contacts
in a zone.
1.12 Smoke detectors
This burglar alarm centre allows the connection
of smoke detectors. For these, program zone
type ”fire” or ”smoke detector”, depending on the
function of the smoke detector. This
programming results in a special acoustic
warning for persons present (pulsed alarm tone).
1.13 Glass breakage detectors
Two kinds of glass breakage sensor can be
connected to this burglar alarm centre:
1.13.1 Acoustic glass break detectors
These glass breakage sensors evaluate acoustic
signals resulting from glass breakage.
1.13.2 Passive glass break detector
Passive glass breakage sensors are fixed direct
to the glass pane to be monitored. Only passive
glass breakage sensors can be used that require
no line feed but offer a potential-free alarm
contact.
1.14 Outdoor bell and strobe
To deter burglars and alert the neighbourhood,
we recommend connecting a bell and a strobe to
the alarm centre.
Note that these alarm devices should be
mounted as high as possible (e.g. at roof height)
and the cables should not be visible. Outdoor
acoustic alarms can be a disturbance to the
neighbourhood. Observe country-specific
regulations. We recommend a maximum alarm
duration of three minutes. A visual alarm (strobe)
remains active until it is acknowledged manually.
In addition to a bell and strobe, we recommend
connecting the tamper contact of the combination
signalling device to the tamper input of the alarm
centre. If the bell housing is opened or the
connection broken, the interrupted tamper
contact triggers a tamper alarm.
101


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Abus Terxon LX - AZ4200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Abus Terxon LX - AZ4200 in the language / languages: English as an attachment in your email.

The manual is 1,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Abus Terxon LX - AZ4200

Abus Terxon LX - AZ4200 User Manual - English - 16 pages

Abus Terxon LX - AZ4200 Installation Guide - German - 31 pages

Abus Terxon LX - AZ4200 User Manual - German - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info