Installation
30 | EN
Step 5: Mount the sounder on the wall
Note
A pin serves as an anti-removal wall contact to activate the tamper switch on the inside of the
sounder. To fit uneven walls, the length of this pin can be adjusted. To do this, turn the screw,
which is in the pin, either in or out.
If the wall tamper contact is still not triggered in the case of extremely uneven walls, you can snap
the pin firmly into place by turning it. Tamper detection for the wall is thus deactivated.
Caution
With this installation, the sounder can be torn off the wall without a tamper alarm being triggered.
Equally, if the sounder is missing it is no longer possible for an alarm to be signalled. The sounder
also loses its certification for security level 2 as a result.
To prevent this, the tamper mechanism can be fixed to the wall, and will break off at the defined
predetermined breaking points in the event of a tamper attempt, recognising a tamper alarm.
Place the sounder on the wall and align it vertically using the integrated spirit level. Mark the
three fixing points.
Note
You can also fix the tamper mechanism to the wall.
Note
The appendix also contains a drilling template.
Drill the holes in the wall to fit the diameter of the screw anchors. Insert the screw anchors
supplied, in the holes.
Insert the screws supplied through the sounder’s fixing holes. Turn the screws in the screw
anchors. Do not tighten the screws yet.
Vertically align the sounder again using the spirit level. Now tighten the screws.