Installation
28 | EN
Installation
Installing the sounder
Step 1: Select installation location for the sounder
Select an installation location which:
is inaccessible to intruders and vandals
is located well out of reach (>3 m)
is clearly visible, so that it acts as a strong deterrent
is within the wireless range of the alarm panel (max. 500 m outdoors).
Note
The wireless signal strength should be tested using the test box at the installation loca-
tion for the sounder and the alarm panel prior to installation.
The sounder must not be installed in the following locations:
at a distance of less than 1 m from large metal structures such as metal doors or frames,
water tanks, refrigerators or cars
at a distance of less than 1 m from household electrical systems, distributors or metal pipes
inside metal housings
close to high-voltage devices or electronic devices such as computers, photocopiers or
other wireless devices
Step 2: Open the sounder’s cover
Open the two covers for the two lid-fixing screws (see Fig. 1).
Remove the fixing screws and open the cover.
Step 3: Configure the sounder’s jumpers
Remove the jumper/connector cover (see Fig. 1) by pushing the two fixing tabs (see Fig. 1)
outwards and lifting up the cover at the same time.
Set all the jumpers in the sounder to the desired positions (see Fig. 3).