671884
21
Zoom out
Zoom in
Previous page
1/32
Next page
21
20
2.8.2 Cleaning
1. Close the gas supply and demount
the burner after it has cooled down,
2. Disconnect the burner, pilot pipe and
thermo couple from the gas control
block (see Figure 11),
3. Remove the complete burner
assembly,
4. Clean the burner with a soft brush.
5. Check the pilot burner and clean it if
so required,
6. Check the combustion chamber, flue
tube and flue baffle and clean these
if required,
7. Re-mount in reverse order. Tighten
the thermo couple connection on the
gas control block hand tight and
tighten it further with a wrench to a
maximum of 1/4 turn as it only needs
to make contact.
After cleaning of the pilot- and main
burner the operation of these should be
checked. If necessary the burner
pressure of the main burner should be
reset.
2.8.3 Inspection of the internal
waterside surfaces
Formation of lime scale depends on the
quality and quantity of the water used.
In addition higher water temperatures
lead to more deposit in the appliance. A
temperature setting of 60°C is
recommended in order to keep the
calcification at a low level.
Decalcification should be attempted with
the proper means. For extensive
information a decalcification instruction
is available.
2.8.4 Spare parts
To be able to order spare parts it is
important to note the type of appliance
as well as the serial number of the
appliance. Based on this information the
data concerning the spare parts can be
determined.
2.9 Inlet combination
Not applicable in U.K. and Ireland.
Figure 11- Mounting burner-set
AOS 0488
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith EQ 155 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith EQ 155 in the language / languages: English as an attachment in your email.

The manual is 1,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith EQ 155

A.O. Smith EQ 155 User Manual - German - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info