19
2.8.1 Sacrificial anode
The life cycle of the anode is determined
by the quality and the quantity of the
water flowing through the apparatus. It
is therefore recommended that the
anode be inspected and replaced if
necessary at least once a year.
1. Close the stop cock in the cold water
supply pipe,
2. Open the nearest hot water tap in
order to allow the pressure to drop
from the water heater and the pipes,
3. Slacken the anode with a fitting
wrench,
4. Check the anode and replace it if it
has been reduced in diameter by
60% or more at any point on its
length,
5. Check for water leaks.
If it is necessary to replace the anode it
should always be replaced by one of
the same type.
The type of anode required can be
determined on the basis of the type of
the appliance and the serial number.
4.b Conversion from LP-gas to natural
gas:
- Put the pressure regulator into
operation. To do this the
temperature regulating knob
should be pulled straight forward.
Next the red plastic cover that is
now visible, should be removed.
Turn the ‘no pr’ (no pressure
regulation) screw completely up
(see Figure 10).
- Seal this setting with lacquer.
- Remount the burner in reverse
order.
- Open the main gas tap.
- Set the correct burner pressure
(see table above).
5. If necessary adjust the pilot correctly
(see “Pilot adjustment”).
6. Fit the correct sticker from the
conversion set on the appliance so
that it is clear that the appliance has
been converted and on which gas
the appliance operates.
2.8 Maintenance
To ensure safe and efficient operation
of the water heater it is recommended
that it is cleaned and serviced at least
once a year by a qualified competent
person.
Figure 10 - Conversion to another gas
AOS 0487
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith EQ 155 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith EQ 155 in the language / languages: English as an attachment in your email.

The manual is 1,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith EQ 155

A.O. Smith EQ 155 User Manual - German - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info