671884
19
Zoom out
Zoom in
Previous page
1/32
Next page
19
18
G20 G30 G31
Inlet pressure mbar 20 30 37
Burner pressure mbar 10.5 30 37
Diameter main injector mm 3.50 1.95 1.95
Diameter pilot injector mm 2x0.27 0.22 0.22
G20 G30 G31 G20 G30 G31
Inlet pressure mbar 20 30 37 20 30 37
Burner pressure mbar 12.5 30 37 12.5 30 37
Diameter main injector mm 2.35 1.40 1.40 2.60 1.50 1.50
Diameter pilot injector mm 2x0.27 0.22 0.22 2x0.27 0.22 0.22
Procedure:
1. Close the main gas tap in the gas
supply.
2. Demount the burner (see “Cleaning”).
3. Replace the injector of the main
burner and the pilot burner with the
correct injectors from the conversion
set (see tables above).
4.a Conversion from natural gas to
LP- gas
- Put the pressure regulation of the
gas control block out of operation.
To do this the temperature
regulating knob should be pulled
straight forward. Turn the ‘no pr’
(no pressure regulation) screw
down tight (see Figure 10).
- Seal this setting with lacquer.
- Remount the burner in reverse
order.
- Open the main gas tap.
Unit EQ 115 EQ 155
Unit EQH 200
Description
Description
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith EQ 155 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith EQ 155 in the language / languages: English as an attachment in your email.

The manual is 1,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith EQ 155

A.O. Smith EQ 155 User Manual - German - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info