671757
17
Zoom out
Zoom in
Previous page
1/28
Next page
17
16
2.2 Commissioning
2.2.1 Filling the water heater
1. Close the drain tap.
2. Open the cold water tap to the water
heater and open all taps where hot
water can be drained for de aeration.
The water heater is lled as soon as
cold water ows from all taps.
3. Close all hot water taps.
2.2.2 Putting into operation
1. Check to see if the heater is lled
with water by running a little to waste
from a hot water tap connected to the
heater.
2. Check wether the ON/OFF switch is
in OFF-position.
3. Ensure gas supply is fully purged of
air and turn on gas cock.
4. Ensure that power has been correctly
supplied to the unit. Use a voltage
tester to check that the live is to “L”
and neutral to “N”. (Flame detection is
phase sensitive).
5. When rst starting, the controller can
be in the lock out condition: depress
the reset button to free the control.
(After manual reset, an extended
prepurge/waiting time will occur).
6. Switch the ON/OFF switch into ON
position. If the pilot fails to ignite
within 25 seconds the controls will go
to lock out and the reset button will
need to be reset (wait 15 seconds
before attempting reset). It may be
necessary to repeat the lighting
sequence a number of times on the
initial light up if all the air has not
been purged from the gas supply.
7. The main burner pressure has been
factory set but should be checked
once normal operation is established
(see ‘Ratings’ for settings).
8. Set the temperature regulator
to the required setting (see
‘Descalcication’).
Note: If during normal use the reset
button is pressed the gas valves
will close and the automatic ignition
controller will start a new sequence after
releasing the reset button.
2.2.3 Shut down
Note:The water heater should only be
turned off when hot water will not be
required for an extended period (e.g.
holidays); otherwise it should be left on.
To shut down put the ON/OFF switch into
OFF position.
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith BTI 100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith BTI 100 in the language / languages: English as an attachment in your email.

The manual is 0,53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info