688688
368
Zoom out
Zoom in
Previous page
1/421
Next page
Chapter 42 Diagnostic
VMG/XMG Series User’s Guide
368
Think of a virtual path as a cable that contains a bundle of wires. The cable connects two points and
wires within the cable provide individual circuits between the two points. In an ATM cell header, a VPI
(Virtual Path Identifier) identifies a link formed by a virtual path; a VCI (Virtual Channel Identifier)
identifies a channel within a virtual path. A series of virtual paths make up a virtual circuit.
F4 cells operate at the virtual path (VP) level, while F5 cells operate at the virtual channel (VC) level. F4
cells use the same VPI as the user data cells on VP connections, but use different predefined VCI values.
F5 cells use the same VPI and VCI as the user data cells on the VC connections, and are distinguished
from data cells by a predefined Payload Type Identifier (PTI) in the cell header. Both F4 flows and F5
flows are bidirectional and have two types.
segment F4 flows (VCI=3)
end-to-end F4 flows (VCI=4)
segment F5 flows (PTI=100)
end-to-end F5 flows (PTI=101)
OAM F4 or F5 tests are used to check virtual path or virtual channel availability between two DSL
devices. Segment flows are terminated at the connecting point which terminates a VP or VC segment.
End-to-end flows are terminated at the end point of a VP or VC connection, where an ATM link is
terminated. Segment loopback tests allow you to verify integrity of a PVC to the nearest neighboring
ATM device. End-to-end loopback tests allow you to verify integrity of an end-to-end PVC.
Note: The DSLAM to which the Zyxel Device is connected must also support ATM F4 and/or F5
to use this test.
Note: This screen is available only when you configure an ATM layer-2 interface.
Figure 241 Maintenance > Diagnostic > OAM Ping
The following table describes the fields in this screen.
Table 165 Maintenance > Diagnostic > OAM Ping
LABEL DESCRIPTION
Select a PVC on which you want to perform the loopback test.
F4 segment Press this to perform an OAM F4 segment loopback test.
F4 end-end Press this to perform an OAM F4 end-to-end loopback test.
F5 segment Press this to perform an OAM F5 segment loopback test.
F5 end-end Press this to perform an OAM F5 end-to-end loopback test.
368


Need help? Post your question in this forum.

Forumrules
1

Forum

zyxel-vmg8623-t50a

Reset search

  • Bhag bhabTouch and hold a clip to pin it. Unpinned clips will be deleted after 1 hour.Touch and hold a clip to pin it. Unpinned clips Touch and hold a clip to pin it. Unpinned clips will be deleted after 1 hour.Touch and hold a clip to pin it. Unpinned clips will be deleted after 1 hour.Touch and hold a clip to pin it. Unpinned clips will be deleted after 1 hour. be deleted aTouch and hold a clip to pin it. Unpinned clips will be deleted after 1 hour.fter 1 hour.Touch and hold a clip to pin it. Unpinned clips will be deleted after 1 hour.ghg GB ggygbgg Touch and hold a clip to pin it. Unpinned clips will be deleted after 1 hour.Touch and hold a clip to pin it. Unpinned clips will be deleted after 1 hour.Touch and hold a clip to pin it. Unpinned clips will be deleted after 1 hour.Touch and hold a clip to pin it. Unpinned clips will be deleted after 1 hour.b Submitted on 29-9-2022 at 03:00

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ZyXEL VMG8623-T50A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ZyXEL VMG8623-T50A in the language / languages: English as an attachment in your email.

The manual is 14,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info