776118
14
Zoom out
Zoom in
Previous page
1/24
Next page
14
SCHEMI ELETTRICI FUNZIONALI.
GENERAL WIRING DIAGRAMS.
ALLGEMEINE SCHALTPLÄNE.
SCHÉMAS GÉNÉRAUX DE CÂBLAGE.
DIAGRAMAS DE CONEXIONES GENERALES.
F
E
D
C
21 53 4
B
A
1 2 3 4 5
76 98
F
E
D
C
678 9
B
A
DRAFT. CHECKED BY
ACCESSORIES
FILE NAME PAGE N.
DIRECTORY DATE
G G
A.FRIZZIERO A.FRIZZIERO
1/4
MASTER
DOMOTICA
blue wire
28/05/2021
NHI MED LOW VAL1 VAL2 L
WALL PAD
LOW
VAL1VAL2
TO SLAVE UNIT
DELAY MED HI N
CONTACT
L
N
PUMP
L
N
FILTER
L
N
HEATER
N
COOLING
L
HEATING
FUSE
LNGND
IN AC230V DC MOTOR
ROOMCOM1STEP1
DIP SWITCH
321
ON
ME
5
4
WATER
N
L
230V-50 Hz
N
L1
PE KEEP ATTENTION TO DON'T
INVERT PHASE AND
NEUTRAL IN BOTH MASTER
AND SLAVE UNITS.
DIP SWITCH :
1 ON
2 ON
3 ON
4 OFF
5 OFF
SW1~3: Motor speed setting
DIP switch description
SW4
OFF
ON
Control setting
Wall Pad
Infrared Handset Remote Control
SW5
OFF
ON
Pipes Setting
2 pipes
4 pipes
Standard setting as indicated above.
Refer to the manual, for different RPM settings.
HI
MED
LOW
VAL1 TO FIRST SLAVE
VAL2
n11
l11
COIL
TEMPERATURE
PROBE (2)
(OPTIONAL)
WINDOW
CONTACT (1)
Ventilconvettore
Fan coil
Gebläsekonvektoren
Ventilconvecteureurs
Ventilconvectores
CTOP2WF
1 2 3 4 5 6 7 8 9
REVERSO + CTOP2WF + V2AM
AC220V-L
AC220V-N
HIGH
MED
OPEN
CLOSE
LOW
OPEN
CLOSE
HEAT VALVE
COOL VALVE
brown wire
grey wire
black wire
to heat pump or
external unit as free
contact (see note "A"
last page
(2) THE PROBE MUST BE POSITIONED, IN PROXIMITY OF
THE INLET, AS INDICATED IN THE INSTRUCTIONS. IT
WILL MEASURE THE WATER TEMPERATURE AND IN
HEATING MODE, THE FAN WILL RUN ONLY IF THE
TEMPERATURE IS OVER THAN THE 35°C (MINIMUM
THERMOSTAT FUNCTION)
(1) IT IS POSSIBLE TO REMOVE THE ELECTRIC BRIDGE BY
FACTORY AND TO USE THE CONTACT AS A
OCCUPANCY SENSOR. IN THIS SENSE, IF THE CONTACT
IS CLOSED, THE UNIT WILL RUN IN ACCORDANCE TO
ITS SETTINGS. INSTEAD IF THE CONTACT IS OPENED,
THE UNIT WILL BE TURNED OFF AFTER 30 SECONDS.
WHEN THE CONTACT IS CLOSED AGAIN, THE UNIT
WILL RUN IN ACCORDANCE TO ITS SETTING.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Zymbo Reverso SM at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Zymbo Reverso SM in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 0.99 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Zymbo Reverso SM

Zymbo Reverso SM User Manual - English, German, French, Italian, Spanish - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info