460436
48
Zoom out
Zoom in
Previous page
1/85
Next page
C
heck the removable tank fuel gauge
w
hile filling the tank (Fig. E). Stop
filling by loosening the switch button on top of the pump (turn anti-clock-
wise), once the gauge indicates that the tank is full. Never overfill the tank,
especially not when the fuel is very cold (fuel expands when it heats up).
L
et the remaining fuel in the pump flow back into the jerrycan and carefully
remove the pump. Carefully screw the fuel cap back on the tank using the
fuel cap cover. After use, re-store the cover at the rear of the heater. Clean
off any spilled fuel.
Check whether the fuel cap is straight and tightened properly. Reinstall the
removable tank in the heater (cap down). Close the lid.
C SETTING THE CLOCK
It is only possible to set the correct time, when the heater is connected to the
mains and not burning. Use the adjustment keys
ƺ to set the time. First press
either of the two keys to switch on the function (the CLOCK light and the
information display
¹ will start blinking). Next, set the hours using the key on the
left (
Ĭhour) and the minutes using the key on the right (įmin.). Press once to
increase the value by one step. When you hold down the key, the value will
continue going up, until you release the key again. After approximately 10
seconds the blinking will stop and the setting will be locked. 5 minutes after
switching off the heater, the information on the display will disappear and the
heater will automatically switch into the stand-by position.
When the heater has been unplugged for more than 10 minutes (or after a
power failure), the time needs to be set again.
D IGNITING THE HEATER
When used for the first time, a new heater may give out a smell for a short while.
You should therefore provide extra ventilation. Always ignite the heater with the
button Ƹ
. Never use matches or a cigarette lighter.
Just press the button Ƹ to ignite the heater. The button will start blinking,
indicating that the ignition procedure has started. This will take a short while. Once
the heater is burning, the button
Ƹ will remain lit (red). The information display
¹ will show two numbers. The light next to them indicates that these numbers
refer to the temperatures (Fig. G). The actual room temperature is indicated below
ROOM, while the temperature setting is indicated below SET. The latter can be
changed with the adjustment keys
(refer to Section E).
Prior to igniting the heater, always check for sufficient fuel in the removable tank.
E SETTING THE REQUIRED TEMPERATURE
The temperature setting can only be adjusted, when the heater is burning. Use the
adjustment keys
ƺ to adjust the temperatur
e. First press either of the two keys to
switch on the function (the TEMP light next to the information display
¹ will start
blinking). Next, adjust the temperature using the key on the right (
įmin.) to set
the temperature to a higher setting and the key on the left (
Ĭhour) to lower the
temperatur
e. Pr
ess once to incr
ease the value one step. After appr
oximately 10
seconds the light will stop blinking and the setting will be locked (Fig. G).
8
7
6
4
46
E
empty full
G: The requir
ed
temperatur
e on the left,
the measured
temperature on the
right.
F: When the CLOCK
indicator light stops
blinking, the setting has
been locked to the
indicated value.
2 0
set room
k
temp.
clock
2 0 : 1 5
set room
mer save hour min. extension
temp.
vent.
clock
48


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Zibro Kamin SRE 188E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Zibro Kamin SRE 188E in the language / languages: English, German, Dutch, Danish, French, Italian, Spanish as an attachment in your email.

The manual is 2,03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info