J THE CORRECT USE OF 'SAVE'
The 'SAVE' function allows you to limit the temperature. When this function is
activated, the heater will automatically switch off, when the room temperature exceeds
the set temperature by 3°C. Subsequently, when the room temperature has dropped
again to the set temperature, the heater will automatically switch on again.
Activate
t
he 'SAVE' setting by pressing the appropriate
Ƽ k
ey. The SAVE indicator light will
light up (Fig. I). Switch off the function by pressing the SAVE key once again.
Without the 'SAVE' setting your heater will maintain the set temperature by
approximation as well, by adjusting its heating capacity. 'SAVE' is an economy
setting, which you can use when, for instance, you are not present in the room
or to keep it frost-free.
K THE 'FUEL' INDICATOR LIGHT
When the indicator light FUEL lights up, it means that there is only fuel left for 10
more minutes. The count-down of the remaining heating time can be seen in the
information display
¹ (Fig. J). Now you have two options:
̈ you remove the fuel tank and refill it outside the living room (section B) or
̈ you push the button EXTENSION ƾ. By pushing this button, the remaining
heating time will extend to 50 minutes. The heater will automatically switch
back to its lowest position. In the display the number 50 will appear, which
will decline to 10. At the arrival of 10, you will hear an alarm signal every two
minutes, warning you to refill the removable tank. If you do not react, the
heater will extinguish by itself. The heater will also sound a warning signal,
when it switches off. The fuel indicator light will blink, while four lines (--:--)
are blinking in the information display. You can stop this by pressing the
button
Ƹ once more.
Once the heater has used up all its fuel and extinguished, it will take some time,
after the refill, before the heater is completely ready for use again.
L THE 'VENT' INDICATOR LIGHT
When there is insufficient ventilation in the room, an intermittent buzzer will be
heard (approximately once each ten minutes) and the VENT indicator will be lit.
When this signal is given, ensure that the ventilation of the room is improved (e.g.
by opening a door or window a little more), to avoid that the heater shuts off.
When the ventilation of the r
oom is impr
oved, the VENT indicator and buzzer will
be deactivated. When there is still insufficient ventilation, the heater shuts off
automatically. When this occurs,
e -1 1 is displayed and the VENT indicator is
blinking. After improving the ventilation of the room (e.g. by opening a door or
window a little mor
e), the heater can be ignited by pushing the
button
Ƹ again.
If the indicator light continues blinking after extra ventilation, please contact your
Zibro dealer.
M MAINTENANCE
Switch off the heater and let it cool down, before you start any maintenance
work. Also disconnect the plug from the mains.
Your Zibro needs hardly any maintenance. It is, however, important that you clean
the air filter
and the vent filter with a vacuum cleaner and the grid with a
damp cloth, both on a weekly basis. Remove the air filter occasionally (Fig. L) and
clean it with soapy water. Prior to reinstallation, make sure that the air filter has
fully dried.
4
49
I: When the SAVE light
l
ights up, the heater will
automatically switch on
o
r off in order to remain
within a specified
temperature range.
J: When the FUEL
indicator light is lit, the
information display will
show the number of
minutes of fuel left in
the tank.
M
L
Fuel filter
K: A blinking VENT
indicator light is a sign
that you need extra
ventilation.
2 0 : 1 5
set room
er save hour min. extension
temp.
clock
timer save vent fuel
set room
save hour min. extension
timer save vent. fuel
set room
s
ave hour min. extension
timer save vent. fuel
t
50


Need help? Post your question in this forum.

Forumrules
1

Forum

zibro-kamin-sre-172e

Reset search

  • My heater model SR172E has error E2 which is failure to ignite how can I find my local dealer in Tortos or Tarragona Spain Submitted on 10-12-2020 at 16:53

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Zibro Kamin SRE 172E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Zibro Kamin SRE 172E in the language / languages: English, German, Dutch, Danish, French, Italian, Spanish as an attachment in your email.

The manual is 1,41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info