564203
3
Zoom out
Zoom in
Previous page
1/62
Next page
GB
Starting the Stove
Press button for a couple of seconds until the pellet boiler
stove starts.
Pellet Boiler stove start up
CAUTION!
The brazier should be cleaned before each starting.
Before switching on the pellet stove, make sure that the pel-
let hopper is full, the combustion chamber is clean, the glass
door is closed, the power supply plug is connected and the
switch on the back is set to “1.”
The LED is on when the parameter
UT01 on the menu is not on OFF and
the weekly or daily programming are
set.
CAUTION!
It is advisable to use dry wood pellets, up to 6 mm in
diameter.
“Fan” will be displayed on the up-
per display and “ACC” on the lower
one. During this phase the unit
will carry out a diagnosis (around
20 seconds) on the fume extrac-
tion system.
“LOAD WOOD” is the next phase,
which indicates pellets should
be fed. The glow plug will heat
up to light the fire.
When the fume temperature is
50º C (approx. 10 minutes), the
pellet boiler stove will confirm
the ignition: “FirE” will be shown
on the upper display and “ON” on
the lower one.
After this phase, which lasts
around 5 minutes, the heating
power (e.g. po 6) and the room
temperature (e.g. 25°), will be si-
multaneously shown on the upper
display, and the system delivery
water temperature will be shown
on the lower display.
If the flame does not start up correctly within 10 minutes, the
pellet boiler stove jams: you will read the words “ALAR” on the
upper display and the words “NO ACC” blinking on the lower di-
splay. Wait 10 minutes until the cooling phase is completed,
open the door, empty the brazier and start a new light-up.
Pict. 2
Preliminary checks
5
6
1
2
3
4
5
“SET”
LED SYMBOL
DESCRIPTION
1
2
3
4
5
6
The LED starts up every time the stove
is loading pellets
The LED blinks when the board signa-
lises a change in temperature or power
set by the infrared remote control.
The LED is on when the room tempera-
ture reaches the value set on the menu
SET Water.
The LED blinks to indicate that you are
entering the menu user/technician or
that you are modifying the temperature
set.
The LED switches on when the water
circulator is working.
Control Panel (Pict. 2)
Buttons and are used to adjust temperature, for
displays and for the programming functions.
Buttons and are used to adjust heating power.
Button is used to adjust temperature and programming
functions.
The upper and lower displays are used to view different
messages.
How to load pellets in the tank
You can load pellets in the tank through the door on the up-
per part of the stove.
Join the following procedure to load pellets:
• Open the door on the upper part of the stove;
• Load the wished pellets quantity with caution (load enough
pellets to grant a sufcient functioning of the stove);
• Close the door.
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Zibro DONATA 194 IDRO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Zibro DONATA 194 IDRO in the language / languages: English, German, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 8,73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info