540049
26
Zoom out
Zoom in
Previous page
1/32
Next page
26
PG-006_v01
Make sure that the power cable does not touch
the hot burners when using the hob.
The earthing wire must be connected to the
terminal marked with the symbol
. The
electrical installation supplying the hob should
be protected with a properly selected safety
device and, in addition, it should be equipped
with a suitable switch enabling the current to
be cut off in an emergency situation.
WIRING DIAGRAM
yellow-green
brown
blue
Make sure that the mains voltage corresponds to the
voltage on the rating label located on the appliance
casing.
The earthing wire (green and yellow in colour) must be at
least 20 mm longer than the phase and neutral wire.
The hob is designed to be connected to a 230 V 50 Hz AC
electricity supply and should be connected to a mains socket
equipped with a properly connected earthing contact.
If the electrical installation is damaged, connecting the
hob to the socket without an earthing contact will create
the risk of electric shock.
The installer is obliged to ll in the warranty
card, which is the basis for warranty claims.
Changing the nozzles for di erent
type of gas (Fig. B)
Nozzles can be changed only by a certi ed
installation technician.
The gas hob is equipped with nozzles adapted for use with
2E (G20) gas.
Type of gas, its pressure, thermal power and designation for
particular burners are shown in the tables below:
Gas hob ZPG6214XZ, ZPG6134SZ, ZPG6145XZ,
ZPG6155SZ
BURNER GAS PRESSURE NOZZLE
DESIGNATION
THERMAL
POWER
SMALL
2E (G20)
3B/P (G30)
20 mbar
37 mbar
0,72
0,5
1000 W
1000 W
MEDIUM
2E (G20)
3B/P (G30)
20 mbar
37 mbar
0,98
0,65
2000 W
1700 W
LARGE
2E (G20)
3B/P (G30)
20 mbar
37 mbar
1,23
0,8
3000 W
2500 W
WOK
2E (G20)
3B/P (G30)
20 mbar
37 mbar
4×0,72; 1×0,81
5×0,5
4500 W
4500 W
Gas hob ZPG6165XZ, ZPG6175SZ, ZPG6185XZ,
ZPG6194XZ, ZPG6204SZ
BURNER GAS PRESSURE NOZZLE
DESIGNATION
THERMAL
POWER
SMALL
2E (G20)
3B/P (G30)
20 mbar
37 mbar
0,72
0,5
1000 W
1000 W
MEDIUM
2E (G20)
3B/P (G30)
20 mbar
37 mbar
0,97
0,65
1750 W
1750 W
LARGE
2E (G20)
3B/P (G30)
20 mbar
37 mbar
1,15
0,85
3000 W
3000 W
WOK
2E (G20)
3B/P (G30)
20 mbar
37 mbar
1,35
0,98
3800 W
3800 W
1
Remove the burner cap and crown.
2
Unscrew the nozzle using a special spanner.
3
Replace the nozzle with that for a new type of gas
according to the table.
After changing the nozzles, adjust the burners (see
“FLAME ADJUSTMENT”).
After changing the nozzles af x an appropriate
label showing the new type of gas at the hob
connecting pipe.
Technical Parameters
The technical parameters are indicated on the rating label.
The hob is equipped with a threaded connecting pipe
G1/2’’ used for connecting to the gas mains. In the case of
connecting the hob to liquid gas (propane-butane) tanks the
tting for 8 x 1 mm hose must rst be screwed onto the
connecting pipe.
The gas hob is a class 1 appliance equipped with a power
cord with an earthing wire. It must be connected to the mains
socket equipped with an earthed pin.
The appliance satis es the requirements of relevant
standards.
The appliance complies with the following directives:
Appliances burning gaseous fuels (GAD) – 90/396/EEC,
93/68/EEC.
Low Voltage Directive (LVD) – 2006/95/EC.
Electromagnetic Compatibility (EMC) – 2004/108/EC.
The product is marked with the CE symbol on the rating
label.
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Zelmer ZPG6175SZ at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Zelmer ZPG6175SZ in the language / languages: English, Polish as an attachment in your email.

The manual is 0,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info