The vacuum cleaner is also equipped with a mechanic
suction power controller, which is situated on the hose
handle. You may use it to slightly regulate the suction power
without the need to use the dial.
Installing/deinstalling the CYKLON dust
container
The vacuum cleaner is equipped with a removable CYKLON
dust container (which is a removable part of the vacuum
cleaner) responsible for collecting dirt. After the CYKLON
dust container is full, it has to be emptied.
Thevacuumcleanerisequippedwithasafety
valve situatedin the chamberof the vacuum
cleaner. It opens up automatically when the
suctionhoseoranyelementsattachedtoitare
completelycloggedup,andwhentheCYKLON
dustcontainer isoverlled.Afterthe valveis
open,youwillhearacharacteristicutteringin
thevacuumcleaner.
1
Press the on/off button (6) to stop the vacuum cleaner.
Remove the plug of the cord from the socket.
2
Turn the end of the suction hose counter-clockwise, and
remove the end of the hose from the inlet of the vacuum
cleaner.
3
Release the fastening of the upper cover (5), and open it.
4
Remove the CYKLON dust container from the vacuum
cleaner. In order to do this hold the body of the vacuum
cleaner by one hand, grab the special handgrip situated on
the cover of the dust container by the other, and by holding
it like that gently remove the CYKLON dust container out of
the vacuum cleaner.
5
Pull the fastenings on the cover of the CYKLON dust
container aside, and remove the cover from the container.
6
Move the CYKLON dust container over a dustbin, and
empty its contents.
After doing this, check the HEPA H12 basic
lter,andcleanorreplaceit,ifnecessary.
7
Place the cover of the CYKLON dust container on the
container in such a way that the fastening situated in the
front part of the cover is inserted into the projection of the
container. Press the back part of the cover in such a way that
the fastenings are shut tight on the body of the container.
The CYKLON dust container has to be shut
tight. Otherwise, the suction power of the
vacuumcleanerisgoingtodrop.
8
Place the emptied CYKLON dust container into the
chamber of the vacuum cleaner. Close the upper cover of the
vacuum cleaner by pressing it, until you hear a characteristic
“click.”
It is necessary to empty the CYKLON dust container, if you
notice that:
a) the vacuum cleaner works less efciently,
b) the CYKLON dust container is full.
C
Deinstalling the lters
The vacuum cleaner is equipped with the CYKLON dust
container based on cyclone ltration, making it possible to
use the vacuum cleaner without a dust bag. A cyclone lter
uses air stream swirling to separate solid dirt. Separation
of dirt is done in an O-shaped part of the container, where
the swirling air casts away dirt on the wall of the container,
and then through the hole into the adjacent chamber of the
container. This pre-ltered air is directed into the washable
HEPA H12 conical lter stopping the tiniest fractions of dust.
A special ltration material used in the washable HEPA H12
lter makes it possible to rinse the lter with running water, if
it is dirty, and reuse it later.
At the outlet of the vacuum cleaner there is a microlter
installed.
In case the HEPAH12 basic lter (14)or the
outlet microlter (13) are dirty, they can be
replacedwithnewones,cleanedorrinsedwith
runningwater.
It is forbidden to wash lters in washing
machinesordishwashers.
Filtersmaybedriedonlynaturally.
Donotusehairdryers,heatersorradiatorsto
drylters.
Before replacing the lters make sure the
vacuumcleanerisoff,andtheplugofthecord
isunpluggedfromthesocket.
HEPA H12 BASIC FILTER
It is necessary to periodically clean the HEPA H12 basic lter
to remove small fractions of dust.
Remove the CYKLON dust container and empty it, as
described in para. C.
1
Pull the fastenings on the cover of the CYKLON dust
container aside, and remove the cover from the container.
If the CYKLON dust container is full, empty it as described in
para. C.
2
Remove the protective casing of the HEPA H12 basic
lter out of the dust container. In order to do this turn the
protective casing of the HEPA H12 basic lter in the direction
given on the symbol (it is situated along with an arrow
on the protective casing of the HEPA H12 basic lter).
Clean, wipe, and carefully dry the casing.
3
Remove the HEPA H12 basic lter from the container
Clean the pleats of the HEPA H12 basic lter
(14), and
if the lter is damaged, it should be denitely replaced
with a new one. If the HEPA H12 basic lter (14) is dirty,
you may replace it with a new one, clean it or rinse it with
running water. Before reinstalling the lter, make sure it
is dry.
Forsafetyreasonsitisunacceptabletoinstall
awetordamagedHEPAH12basiclter(14).
D
57


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Zelmer Tiny VC1400.0 SK at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Zelmer Tiny VC1400.0 SK in the language / languages: English, Polish as an attachment in your email.

The manual is 3,95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info