539666
62
Zoom out
Zoom in
Previous page
1/66
Next page
66 VC3100-001_v01
Whendrawingoutthepowercableyouhaveto
payattentiontoyellowbandindicatingtheend
ofthecabledrawnout.Furtherattempts(jerks)
mayleadtodamageofthecable.
7
Plug the cord into an AC outlet.
Before you start vacuum cleaner make sure whether the dust
container “CYCLONE” is mounted in chamber of the vacuum
cleaner, and whether the inlet and outlet lters are mounted
in the vacuum cleaner.
8
Start the vacuum cleaner by pressing On/Off button (4).
9
Vacuum cleaner is equipped with electronic power
regulator, which - during the vacuuming - can smooth control
the suction power of vacuum cleaner. By turning the knob
(4) right or left you can increase or decrease the suction
power.
10
Vacuum cleaner is also equipped in mechanical control
of suction power (9), which is located on the handle of the
hose. It can temporarily slightly adjust the suction power,
without adjustment done with knob (4).
Disassembly/assembly of “CYCLONE”
dust container
Vacuum cleaner is equipped in removable dust container
“CYCLONE” (which is a removable segment of vacuum
cleaner), which accumulates contaminants. As soon as the
“CYCLONE” dust container is full, it should be emptied.
Vacuum cleaner is equipped with a safety
valve whichis locatedin thechamber ofthe
“CYCLONE” dust container. The valve is
activated (open) automatically when a total
jam (occlusion) occurs on the sucking hose
orthishappenstoequipmentconnectedtoit,
aswellasin thecaseofexcessiveoverllof
“CYCLONE” dust container. When the valve
is open you can hear a characteristic sound
(“asoundofutter”)inthevacuumcleaner.
1
Vacuum cleaner is equipped with a dust container
“CYCLONE” full indicator (5). When the gap of dust container
“CYCLONE” full indicator is totally lled with red mark during
operation (vacuum cleaner operates at full power and
sucker nozzle or brush is upraised over cleaned surface)
so this informs that there is a need to empty the dust bin
“CYCLONE”. The dust container “CYCLONE” full indicator
(5) may work also in the case of clogging of the suction hose
or clogging of equipment connected to the hose.
2
Switch off the vacuum cleaner by pressing On/Off
button (4).
3
Take off the cable connection plug from the wall outlet.
4
Press the two side buttons on the hose end , then remove
the hose end from vacuum cleaner inlet hole.
5
Raise the hook to unlock the dust container “CYCLONE”
(7) and remove dust container “CYCLONE” (16) from the
vacuum cleaner.
C
6
Move the dust container “CYCLONE” on garbage trash.
Press the button located on dust container “CYCLONE”, the
bottom of the container will open and the contents will fall out
to the trash.
7
After emptying the container, snap the bottom. Pay
attention to the fact that a seal located on the bottom of
container must be correctly positioned.
Containermustbepreciselyclosed.Otherwise
the dust will penetrate the vacuum cleaner
chamberandthesuctionpowerwilldecrease.
8
Insert the empty dust container “CYCLONE” to vacuum
cleaner. The characteristic “click” indicates that container
has been mounted correctly.
Emptying the dust container “CYCLONE” is necessary when
you notice that:
a) “CYCLONE” dust container full indicator indices turned on,
b) sucking power of vacuum cleaner decreased,
c) dust container “CYCLONE” is full.
Disassembly of lters
In case of dirty lters: inlet lter, foam lter
(15),HEPAinletlter(14),outletfoamlter(13),
“Microlter” (12) you can replace them with
new lters, clean them or rinse with running
water.
Donotwashthelterinthewashingmachine
ordishwasher.
Filterscanbedriedinnaturalwayonly.
Do not dry the lters using hairdryers, on
heatersandradiators.
Before replacement of lters make sure that
vacuumcleanerisswitchedoffandconnection
cableplugispulledoutfromthewalloutlet.
INLET FILTER HEPA AND FOAM INLET FILTER
Vacuum cleaners are equipped with outlet lter HEPA (High
Efciency Particulate Air) type H10 or H13.
These lters have exceptionally high ltration capacity, are
made of special bers, which can retain almost all dust
particles. The lter standards H10 and H13 dene the
permeability of the lter: H10 lter can retain 85% of particles
diameter of 0.3 microns, and H13 lter up to 99.95% of all
impurities.
It is necessary to clean periodically the inlet lter HEPA (14)
in order to remove minor fractions of the dust, and foam inlet
lter (15) must be also cleaned.
Disassembly the “CYCLONE” dust container and empty it in
accordance with paragraph (C).
1
Remove the HEPA foam inlet lter (14) from “CYCLONE”
dust container
2
Remove foam inlet lter (15). If the foam inlet lter (15)
is dirty, you can replace it with a new lter, you can clean
D
62


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Zelmer Eco Power VC3100.0 SK at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Zelmer Eco Power VC3100.0 SK in the language / languages: English, Polish as an attachment in your email.

The manual is 4,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info