539647
61
Zoom out
Zoom in
Previous page
1/66
Next page
65
agent recommended by ZELMER S.A. in the amount and
manner indicated on the label.
„G 478 Entschäumer D” manufactured by the company
BUZIL, Germany.
Prepare the vacuum cleaner for operation according
to section B.
ATTENTION! Use only the large or small atomizing
nozzle for wet vacuum cleaning.
The vacuum cleaner will by default begin operation at the
medium power range. 3 diodes will light on the power
level indicator (9). Set the desired power value (this
function is only available in vacuum cleaners type 919.0)
by pressing the power adjustment buttons +/- (8).
7
Press the pump switch (6).
ATTENTION! The pump may only be switched on when
the cleaning liquid container is lled with the solution
of cleaning liquid and water. The lack of cleaning liquid
manifests in a loud operation of the pump.
If the nozzle does not atomize water although the pump is
switched on, check if the following items are correctly installed:
the cleaning liquid container (press the container), the fastening
of the stub pipe in the valve in the base of the vacuum cleaner
or the fastening of the hose end in the atomizing nozzle, check
if the atomizing nozzle is not clogged.
8
Press the button adjusting the inow of water to the
nozzle on the hose handle.
If you press the button in a pulsating manner, the water shall
temporarily ow in a slower manner to the nozzle, if you
press and slide the button backwards, the water shall be
continuously supplied to the nozzle.
The handle is also equipped with a slider to adjust the suction
power. Do not uncover this opening while picking up water or
using the wet cleaning function.
ATTENTION! Do not spray the cleaning liquid in one
place on the carpet for too long in order not to soak
the carpet.
After cleaning one part of the carpet stop the spraying
process and dry the carpet by sliding the nozzle back and
forth. Repeat until the whole surface of the carpet is dried.
After ending the spraying process switch off the pump
and press the button adjusting the water inow to the
nozzle for a moment to “release the pressure”.
ATTENTION! The vacuum cleaner is equipped with a oat
which will automatically block the suction if the foamlter
II (32) is heavily dirty or the liquid exceeds the maximum
level. It is manifested by a pulsing limitation of the motor
power and the lighting up of the clogged air inlet indicator
(11) (type 919.0). In such a case switch off the vacuum
cleaner by pressing the on/off button (7), unplug the
appliance, clean the lter and empty the container.
In case of dirt which is difcult to remove moisten the surface
with the washing agent recommended by ZELMER S.A. until
foam is formed. Leave for some time and vacuum with the
vacuum cleaner.
ATTENTION! Make sure the carpet is not soaked.
It may lead to a permanent deformation of the carpet
(folding).
PICKING UP WATER
If you want to use the vacuum cleaner to vacuum liquid in
the container, the vacuum cleaner should be prepared as in
the case of vacuum cleaning with the use of the water lter
module except that:
1. The container should be empty (without water).
2. You are to use atomizing nozzles (large or small), large
atomizing nozzle with the gathering attachment or the
nozzle for picking up water.
ATTENTION! Do not operate the vacuum cleaner with
a full container! Do not vacuum large amounts of liquid
at a time (e.g. with the hose immersed into water).
If the water exceeds the maximum level during vacuuming,
the oat will automatically block the suction. The maximum
capacity of the container is about 5 l. In such a case proceed
in the manner described above in the part concerning the
blocking of suction caused by a dirty foam lter (pulsating
motor speed).
END OF OPERATION CLEANING AND MAINTENANCE
Switch off the vacuum cleaner by pressing the on/off
button (7) and unplug the appliance.
Wind the cord by pressing the cord rewind button
(10).
While doing this hold the cord to make sure it is not
tangled and the plug does not hit the vacuum cleaner
housing.
Turn the end of the hose until the tops of the marks
on the end of the hose end and on the vacuum cleaner
housing are in the same position and pull the hose out
of the opening.
Remove the stub pipe of the hose by pressing the red
button on the valve and pull the stub pipe.
Disconnect the telescopic tube from the hose and the
nozzle or brush.
Pour the dirty water out of the container.
It is recommended to wash the container, lters
(disassembly below) and partition thoroughly after each
use – changing water several times.
After using the wet cleaning function thoroughly wash
all attachments used in this process (hose, tubes,
accessories).
ATTENTION! If you do not clean the above-mentioned
parts or clean them insufciently it may lead to the loss
of the ltration capabilities of the inserts and foam and
cause the formation of bacteria and mites.
Dry all the cleaned parts thoroughly before reassembly.
61


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Zelmer Aquawelt 919.5 SK at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Zelmer Aquawelt 919.5 SK in the language / languages: English, Polish as an attachment in your email.

The manual is 5,41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info