539648
60
Zoom out
Zoom in
Previous page
1/66
Next page
64
atomizing nozzle or the large atomizing nozzle until you hear
a characteristic click.
15
Use the following nozzles for the wet vacuuming and wet
cleaning function or to pick up water: large atomizing nozzle,
small atomizing nozzle or the water pick up nozzle.
16
Slide the stub pipe valve plug downwards.
Insert the stub pipe of the hose to the valve in the
vacuum cleaner housing.
Make sure the stub pipe fastenings snap shut.
ATTENTION! In case of difculties in connecting the
above mentioned elements moisten the gaskets e.g.
with technical vaseline, water, etc.
Vacuum cleaner functions
TRADITIONAL CLEANING WITH SAFBAG DUST BAG
1
Press and hold the container lid opening button (2) and
lift the container lid.
2
Remove the water lter module from the container
(ltration unit and partition).
3
Insert the dry ltration module with the SAFBAG (21)
dust bag to the container.
Prepare the vacuum cleaner for operation according
to section B.
4
The vacuum cleaner will by default begin operation at
the medium power range. 3 diodes will light on the power
level indicator (9). Set the desired power value (this function
is only available in vacuum cleaners type 919.0) by pressing
the power adjustment buttons +/- (8).
ATTENTION! The vacuum cleaner is equipped with
a power limiting function should the inlet opening be
clogged or the SAFBAG dust bag full. It is manifested
by a pulsing limitation of the motor power and the
lighting up of the clogged air inlet indicator (11) while
the vacuum cleaner is operating at full power (type
919.0). In such a case switch off the vacuum cleaner
by pressing the on/off button (7), unplug the appliance
and clear the tubes or replace the SAFBAG dust bag.
SAFBAG dust bag disassembly/assembly
Remove the dry ltration module with the SAFBAG
(21)
dust bag from the container.
1
Pull the SAFBAG dust bag interlock fastening and pull
the interlock aside.
2
Pull the fastening which attaches the SAFBAG dust bag
to the basket to release the dust bag plate.
3
Remove the dust bag.
4
Insert the SAFBAG dust bag according to the arrow
printed on the bag so that the lower part of the bag plate is in
the slot of the housing. Press the upper part of the bag plate
to the fastening until you hear a characteristic click and close
the SAFBAG dust bag interlock.
Insert the dry ltration module with the SAFBAG
(21)
dust bag to the container.
VACUUM CLEANING WITH THE USE OF THE
WATER FILTER MODULE
1
Press and hold the container lid opening button (2) and
lift the container lid.
2
Insert the partition to the grooves in the container so that
the shutters are directed downwards. Make sure the partition
is correctly mounted in the container i.e. the partition ns
should cover the protrusion in the container.
3
Fill the container with 1,3–1,5 liter of water. The water
level should be in the range marked on the wall of the
container.
ATTENTION! Do not operate the appliance with an
empty container while vacuum cleaning with the use
of the water lter module.
4
Cover the container with the lter unit.
Prepare the vacuum cleaner for operation according
to section B.
The vacuum cleaner will by default begin operation at the
medium power range. 3 diodes will light on the power
level indicator (9). Set the desired power value (this
function is only available in vacuum cleaners type 919.0)
by pressing the power adjustment buttons +/- (8).
ATTENTION! Do not operate the appliance for too long
without replacing the water in the container.
WET VACUUMING AND WET CLEANING
Before using the wet cleaning function thoroughly vacuum
the surface to be cleaned.
Before operating the vacuum cleaner make sure the container
is empty and the water lter module and the lters are clean.
1
Press and hold the container lid opening button (2) and
lift the container lid.
2
Remove the container together with the water lter
module (lter unit and partition) from the vacuum cleaner.
3
Remove the cleaning liquid container (23) by pulling it by
the handle and lifting it upwards.
4
Open the inlet plug and ll the cleaning liquid container
(23) with the cleaning liquid (the solution of cleaning powder
and water) in the amount indicated below:
Dissolve the content of the bag in a separate container
in 1,5 l of warm water with the maximum temperature
of 50°C. The maximum capacity of the cleaning liquid
container is 1,7 l.
Close the inlet plug of the cleaning liquid container
5
Insert the cleaning liquid container (23) back to the
previous position and press the container to x it correctly
(proceed in the reverse order as in case of removing the
container).
6
Insert the container together with the water lter module
(lter unit and partition) to the vacuum cleaner.
In order to protect from the foam formation or if foam
forms during the cleaning process, use the anti-foam
C
F
E
D
60


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Zelmer Aquawelt 919.0 SP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Zelmer Aquawelt 919.0 SP in the language / languages: English, Polish as an attachment in your email.

The manual is 5,41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info