Gas Burners Rating
Rapid Burner (big) 2,9 kW (G20/G25) - 2,7 kW (G30/G31)
Semirapid Burner (medium) 1,9 kW
Auxiliary Burner (small) 1 kW
Appliance Class : 3
Category II2E+3+
Setting Natural Gas 20 mbar / G25 25 mbar
Gas connection G 1/2"
Electric Supply 230 V 50 Hz
HOB RECESS
DIMENSIONS
Length 550 mm.
Width 470 mm.
""
""
" The following instructions about installation
and maintenance must be carried out by qualified
personnel in compliance with the regulation in
force. The regulation to be applied for this type
of installation is NBN D 5I.003 : "Installations
functioning with combustible gas lighter than
air".
""
""
" The side walls of the unit in which the hob is
going to be installed, must not exceed the height
of the working top.
""
""
" Avoid installing the appliance in the proximity of
inflammable materials (e.g. curtains, tea towels
etc.).
""
""
" The appliance must be electrically disconnected
before all interventions. If any electric supply to
the appliance is required to carry out the work,
ensure all the necessary precautions are
followed.
Gas connection
It is indispensible that the connection to the gas mains
are carried out by means of an AGB tap. Choose fixed
connections or use a flexible pipe in AGB (stainless
steel).
If using flexible metallic pipes, be careful they do not
come in contact with mobile parts or they are not
squeezed. Use the same attention when the hob is
combinated with an oven.
This hob can be operated by Slochteren gas (G25) with
a nominal pressure of 25 mbar or by natural gas with
nominal pressure of 20 mbar. No regulation is required
for use by these two types of gas.
Before fitting the appliance ensure that the installation
has the correct voltage for the appliance. At full
capacity, the drop in pressure must not exceed 5%.
Such a drop in pressure is caused by the following
parameters:
- maximum capacity of meter;
- diameter and lenght of the tube in front and behind
the meter;
- section of transit of variuos tubes positioned on the
circuit;
- diameter of eventual connections.
IMPORTANT - To ensure a correct operation, a saving
of energy and the long-life of the appliance, the voltage
pressure of the appliance must correspond to the
recommended values.
The adjustable connection is fixed to the comprehensive
ramp by means of a threaded nut G 1/2".
All the components shown in Fig.4 have already been
assembled in the factory.
The appliance, before leaving the factory, has been
tested in order to give you the best results.
IMPORTANT - When the final connection has been
made, it is essential that a thorough leak test is carried
out on the hob and installation. Use some soapy water,
never a flame.
A) Ramp with ending nut
B) Seal
C) Adjustable connection
Fig. 4
FO 2365
Technical Data
Instruction for the Installer
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Zanussi zgg 643 ica n w y at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Zanussi zgg 643 ica n w y in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 1,26 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info