6-4
IM 1F5B2-01E
6.5 Action Against Power Failure
In the case of a power failure, the totalized data value is protected by the EEPROM.
ULTRA YEWFLO cannot operate during a power failure, however, resulting in an
interruption in totalization. It resumes totalization upon recovery from the power
failure (restarts totalization, beginning with the value given immediately before the
power failure) and automatically restores normal operation.
•No backup batteries are necessary for the EEPROM.
6.6 Precautions During Startup
Because of effects due to external noise, ULTRA YEWFLO may not indicate 0%
when the flowrate is zero, giving an output greater than 0%. If this occurs, first make
sure ULTRA YEWFLO is filled with the process fluid. Then, make a TLA adjust-
ment according to the instructions in Subsection 8.2.3.
If the pipeline is empty during startup, ULTRA YEWFLO may continue to give a 0%
output or remain unstable until it fills with the process fluid.
IMPORTANT
•Whenever possible, pipe ULTRA YEWFLO while exercising care to prevent bubbles
of gas from mixing with the process fluid. (See Section 4.1, “Piping Precautions.”)
41


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yokogawa UYF200 Ultrasonic Vortex Flowmeter at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yokogawa UYF200 Ultrasonic Vortex Flowmeter in the language / languages: English as an attachment in your email.

The manual is 0,93 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info