<Appendix B. Device Information>
B-2
IM 01C25R51-01E
B-2 How to Congure digitalYEWFLO AR Block
This section explains how to set the function block scheduling and connection information with
the following device as an example.
I
nthisexample,NI-FBUSCongurator3.1isusedasasettingtool.
Table B2.1 Object device (Case 1: AR Block is standalone)
Value Device
Function
Block
Input to
AR Block
Output from
AR Block
Factory setting
of scheduling
information
(1) Mass Flow Rate digitalYEWFLO AR Block
T
able B2.2 Object device (Case 2: AR Block is connected with other devices)
Value Device
Function
Block
Input to
AR Block
Output from
AR Block
Factory setting
of scheduling
information
(1)
V
olumetricFlowRate
(Qv)
digitalYEWFLO AI3 Block
(2) Temperature
Temperature Transmitter
(Yokogawa YTA320)
AI1 Block
(3) Pressure
Pressure Transmitter
(Yokogawa EJX510A)
AI1 Block
(4) Mass Flow Rate digitalYEWFLO AR Block
Step 1 Conrm the installation status of the device DD.
TosetthedevicebyusingNI-FBUSCongurator,thedeviceDDmustbesuccessfullyinstalledin
the following folder.
<WinInstDrive>:\ProgramFiles\NationalInstruments\NI-FBUS\Data\594543”
(<WinInstDrive>: Windows installed drive)
(
Thefoldername594543”indicatesthatthemanufacturerisYokogawaElectricCorporation.)
TheDDlesaresavedforeachmodelinthefolder.ConrmthatthelatestDDles(FileName:
AABB.ffo, AABB.sym*) are installed for each device.
(
*:AA=DeviceRevision”,BB=“DDRevision,Forexample:0301.ffoand0301.sym)
• digitalYEWFLO:Foldername0009
• YTA320:Foldername0005
• EJX510A:Foldername000C
149


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yokogawa FSA120 Flow Configuration Software at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yokogawa FSA120 Flow Configuration Software in the language / languages: English as an attachment in your email.

The manual is 12,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Yokogawa FSA120 Flow Configuration Software

Yokogawa FSA120 Flow Configuration Software Quick start guide - English - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info