540486
152
Zoom out
Zoom in
Previous page
1/174
Next page
<14. EXPLOSION PROTECTED TYPE INSTRUMENT>
14-1
IM 01F06A00-01EN
14. EXPLOSION PROTECTED TYPE
INSTRUMENT
In this chapter, further requirements and differences
for explosion proof type instrument are described
except TIIS Flame proof. For explosion protected
type, the description in this chapter is prior to other
description in this Users Manual.
WARNING
Only trained persons use this instrument in
industrial locations.
14.1 ATEX
WARNING
Only trained persons use this instrument in
industrial locations.
Electrostatic charge may cause an explosion
hazard.
Avoid any actions that cause the generation
of electrostatic charge, such as rubbing with
a dry cloth on coating face of product.
(1) Technical Data
• Flameproof
Applicable Standard : EN 60079-0: 2009,
EN 60079-1: 2007
Certi cate : DEKRA 11ATEX0212X
Type of Protection:
Groups/Category: II 2 G
Ex d IIC T6…T1 Gb (Integral Type Vortex
Flowmeter and Remote Type Vortex Flow
Detector)
Ex d IIC T6 Gb (Remote Type Vortex Flow
Converter)
Speci cation of Protection:
Process Temperature: (Integral Type Vortex
Flowmeter and Remote
Type Vortex Flow
Detector)
Temperature Class Process Temperature
T6 -29°C to +80°C
T5 -29°C to +100°C
T4 -29°C to +135°C
T3 -29°C to +200°C
T2 -29°C to +300°C
T1 -29°C to +450°C
*1 Note: Use /HT version above 250°C
Temperature Class: T6 (Remote Type Vortex Flow
Converter)
Ambient Temperature:
-29 to +60°C (Integral Type Vortex Flowmeter
and Remote Type Vortex Flow Detector)
-40 to +60°C (Remote Type Vortex Flow
Converter without indicator)
-30 to +60°C (Remote Type Vortex Flow
Converter with indicator)
Power Supply: 10.5 to 42Vdc max.
Output Signal: Current Output; 4 to 20mAdc
Pulse Output; On=2Vdc, 200mA
Off=42Vdc, 4mA
Special Fastener: Class A2-50 or more
• Intrinsically Safe
Applicable Standard: EN 60079-0: 2009,
EN 60079-0: 2012,
EN 60079-11: 2012,
EN 60079-26: 2007
Certi cate: DEKRA 13ATEX0192 X
Type of protection:
Ex ia IIC T4…T1 Ga (Integral Type Vortex
Flowmeter)
Ex ia IIC T6…T1 Ga (Remote Type Vortex Flow
Detector)
Ex ia IIC T4 Ga (Remote Type Vortex Flow
Converter)
Groups/Category: II 1 G
Ambient Temperature:
-29 to +60°C (Integral Type Vortex Flowmeter)
-40 to +80 [79]°C (Remote Type Vortex Flow
Detector)
(Option /LT below -29°C, [ ] for Option /MV at T6)
-40 to +80°C (Remote Type Vortex Flow
Converter without indicator)
-30 to +80°C (Remote Type Vortex Flow
Converter with indicator)
152


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yokogawa DYA Vortex Flow Converter at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yokogawa DYA Vortex Flow Converter in the language / languages: English as an attachment in your email.

The manual is 5,84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info