638628
6
Zoom out
Zoom in
Previous page
1/116
Next page
Page 6 / 116 00CNO0183-C
CONDENSINOX - Installation, Use and Maintenance
!
DANGER:
If you smell gas:
Do not use naked ames, do not smoke and do not activate
electrical contacts or switches.
Cut the gas supply.
Ventilate the room.
Trace the leak and repair it.
!
DANGER:
If smoke is released:
Switch off the boiler.
Ventilate the room.
Trace the leak and repair it.
DANGER:
The boiler is earthed via connecting cables (green/yellow) and special
xing screws. If the boiler is disassembled, make sure the cables are
reconnected properly and ALWAYS reuse the original xing screws.
1.5. Water characteristics
The following rules apply once the boiler is put into service and remain valid
until the end of life of the product.
1.5.1. Preparing the water system before putting the boiler into service
For any installation (new or renovation), the water system pipes must be
thoroughly cleaned. The purpose of this initial cleaning is to eliminate germs
and residue that can cause deposits to form.
In new installations in particular, any residues of grease, oxidised metal or
copper micro-deposits must be removed.
In renovated installations, cleaning should focus on removing sludge and the
products of corrosion formed when the unit was last in operation.
There are two types of methods for cleaning and removing sludge: a high-
intensity approach that takes a few hours and a slower, more gradual
approach that takes several weeks. This rst type of cleaning must be done
before connecting the new boiler, and with the second type, a lter should be
installed on the boiler return circuit to capture loosened deposits.
The cleaning performed prior to installation improves performance, reduces
energy consumption, and resists scaling and corrosion on the unit. A water
treatment professional should carry out the cleaning.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ygnis Condensinox at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ygnis Condensinox in the language / languages: English as an attachment in your email.

The manual is 8,81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ygnis Condensinox

Ygnis Condensinox Installation Guide - Dutch - 74 pages

Ygnis Condensinox Installation Guide - Dutch - 43 pages

Ygnis Condensinox User Manual - Dutch - 18 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info