VX-8GR/GE OPERATING MANUAL 57
SCANNING
HOW TO SKIP
(
OMIT
)
A FREQUENCY DURING VFO SCAN
If the VFO scan stops on a frequency or frequencies that you do not need (such as a
spurious radiation from a television), such frequencies can be “skipped” during VFO scan-
ning. A special “Frequency Skip Memory” bank is reserved to store these frequencies.
To skip a frequency during VFO scanning:
1. While VFO scanning is stopped on the frequency that you do not need, press and hold
the f key for one second, then rotate the DIAL knob to select the desired Fre-
quency Skip Memory channel (900 - 999). The microprocessor will automatically
select the next-available “free” Frequency Skip Memory channel (a memory register
on which no data has been stored). If you see the “ ” icon at the upper left of the
channel number, it means that the channel currently has no data written on it (i.e. the
channel is “free”).
2. Press the f key to store the frequency into the Frequency Skip Memory. It will now
be ignored during VFO scanning.
To re-institute a frequency into the VFO scan loop:
1. Press the c key, if needed, to enter the Memory Recall (“MR”) mode.
2. Press and hold in the f key for one second, then rotate the DIAL knob to select the
memory channel to be re-instituted.
3. Press the d key. The confirmation message (DELETE?) will appear on the display.
Press the d key once more to delete the channel from the Frequency Skip Memory;
this will restore the frequency into the VFO scan loop.
The VX-8GR/GE has 100 VFO Frequency Skip Memory Channels.
VFO SCANNING
SETTING THE SQUELCH LEVEL DURING ACTIVE SCANNING OPERATION
The VX-8GR allows adjustment of the Squelch level “on the fly” while you are
scanning.
1. While the scanner is engaged, press the key,
then press the key (the current squelch level
will appear below the frequency display).
2. Rotate the DIAL to select the desired Squelch level.
3. Press the PTT switch briefly to save the new setting and exit to normal op-
eration. In this case, pressing the PTT switch this one time will not causing
scanning to stop.
59


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yaesu VX-8GE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yaesu VX-8GE in the language / languages: English as an attachment in your email.

The manual is 4,19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info