Group No. Menu Function Available Values Default Setting
RX DSP 107 APF WIDTH NARROW/MEDIUM/WIDE MEDIUM
RX DSP 108 CONTOUR LEVEL -40
ȡ
0
ȡ
20 -15
RX DSP 109 CONTOUR WIDTH 1
ȡ
11 10
RX DSP 110 DNR LEVEL 1 - 15 3
RX DSP 111 IF NOTCH WIDTH NARROW/WIDE WIDE
RX DSP 112 HF
CW SHAPE SOFT/SHARP SOFT
RX DSP 113 HF CW SLOPE STEEP/MEDIUM/GENTLE MEDIUM
RX DSP 114 6M CW SHAPE SOFT/SHARP SOFT
RX DSP 115 6M CW SLOPE STEEP/MEDIUM/GENTLE MEDIUM
RX DSP 116 HF PSK SHAPE SOFT/SHARP SHARP
RX DSP 117 HF PSK SLOPE STEEP/MEDIUM/GENTLE MEDIUM
RX DSP 118 HF FSK SHAPE SOFT/SHARP SHARP
RX DSP 119 HF FSK SLOPE STEEP/MEDIUM/GENTLE MEDIUM
RX DSP 120 HF SSB SHAPE SOFT/SHARP SHARP
RX DSP 121 HF SSB SLOPE STEEP/MEDIUM/GENTLE MEDIUM
RX DSP 122 6M SSB SHAPE SOFT/SHARP SOFT
RX DSP 123 6M SSB SLOPE STEEP/MEDIUM/GENTLE MEDIUM
SCOPE 124 SCOPE MODE CENTER/FIX CENTER
SCOPE 125 SCOPE SPEED FAST/SLOW FAST
SCOPE 126 SCOPE AUTO TIME OFF/3/5/10/30/60 (sec) OFF
SCOPE 127 START DIAL SPEED 0.5/1/2/4/8/16 (kHz/sec) 8kHz/sec
SCOPE 128 CENTER SPAN FREQ 20/50/100/200/500/1000 (kHz) 100kHz
SCOPE 129 FIX 1.8MHz 1800
ȡ
1999 (1kHz/step) 1800kHz
SCOPE 130 FIX 1.8MHz SPAN 20/50/100/200/500/1000 (kHz) 200kHz
SCOPE 131 FIX 3.5MHz 3500
ȡ
3999 (1kHz/step) 3500kHz
SCOPE 132 FIX 3.5MHz SPAN 20/50/100/200/500/1000 (kHz) 500kHz
SCOPE 133 FIX 5.0MHz 5250
ȡ
5499 (1kHz/step) 5250kHz
SCOPE 134 FIX 5.0MHz SPAN 20/50/100/200/500/1000 (kHz) 200kHz
SCOPE 135 FIX 7.0MHz 7000
ȡ
7299 (1kHz/step) 7000kHz
SCOPE 136 FIX 7.0MHz SPAN 20/50/100/200/500/1000 (kHz) 500kHz
SCOPE 137 FIX 10MHz 10100
ȡ
10149 (1kHz/step) 10100kHz
SCOPE 138 FIX 10MHz SPAN 20/50/100/200/500/1000 (kHz) 50kHz
SCOPE 139 FIX 14MHz 14000
ȡ
14349 (1kHz/step) 14000kHz
SCOPE 140 FIX 14MHz SPAN 20/50/100/200/500/1000 (kHz) 500kHz
SCOPE 141 FIX 18MHz 18000
ȡ
18199 (1kHz/step) 18068kHz
SCOPE 142 FIX 18MHz SPAN 20/50/100/200/500/1000 (kHz) 100kHz
SCOPE 143 FIX 21MHz 21000
ȡ
21449 (1kHz/step) 21000kHz
SCOPE 144 FIX 21MHz SPAN 20/50/100/200/500/1000 (kHz) 500kHz
SCOPE 145 FIX 24MHz 24800
ȡ
24989 (1kHz/step) 24890kHz
SCOPE 146 FIX 24MHz SPAN 20/50/100/200/500/1000 (kHz) 100kHz
SCOPE 147 FIX 28MHz 28000
ȡ
29699 (1kHz/step) 28000kHz
SCOPE 148 FIX 28MHz SPAN 20/50/100/200/500/1000 (kHz) 1000kHz
SCOPE 149 FIX 50MHz 50000
ȡ
53999 (1kHz/step) 50000kHz
SCOPE 150 FIX 50MHz SPAN 20/50/100/200/500/1000 (kHz) 1000kHz
TUNING 151 CW DIAL STEP 1/5/10 (Hz) 10Hz
TUNING 152 DATA DIAL STEP 1/5/10 (Hz) 5Hz
TUNING 153 AM/FM DIAL STEP 10/100 (Hz) 100Hz
TUNING 154 RTTY DIAL STEP 1/5/10 (Hz) 5Hz
TUNING 155 SSB DIAL STEP 1/5/10 (Hz) 10Hz
TUNING 156 AM CH STEP 2.5/5/9/10/12.5 (kHz) 5kHz
TUNING 157 FM CH STEP 5/6.25/10/12.5/20/25 (kHz) 5kHz
TUNING 158 1MHz/100kHz SELECT 1MHz/100kHz 1MHz
TX AUDIO 159 PRMTRC EQ1 FREQ 100/200/300/400/500/600/700 200
TX AUDIO 160 PRMTRC EQ1 LEVEL -20
ȡ
0
ȡ
+10 0
TX AUDIO 161 PRMTRC EQ1 BWTH 1
ȡ
10 1
MENU MODE
112


Need help? Post your question in this forum.

Forumrules
1

Forum

yaesu-ftdx1200

Reset search

  • Green Light on VFO A and MEM is flashing and no audio. Even tried Factory Reset and still flashing. How do I fix this? Submitted on 6-12-2022 at 07:37

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yaesu FTDX1200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yaesu FTDX1200 in the language / languages: English as an attachment in your email.

The manual is 14,65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info