674745
138
Zoom out
Zoom in
Previous page
1/154
Next page
Page 136 FT-
991
OperaTing Manual
Menu MODe
131 P-PRMTRC EQ1 LEVEL
Function: Selects the gain setting for the low range of
the 3 band parametric microphone equalizer
when the speech processor is activated.
Available Values: −20 - 0 - 10
(
dB
)
Default Setting: 0
Description: Activates when the speech processor is
“ON”and sets the gain for the low range of
the 3 band parametric microphone equalizer
between “−
20 dB
” and “
+10 dB
”.
132 P-PRMTRC EQ1 BWTH
Function: Selects the width
(
“Q”
)
for the low range of
the 3 band parametric microphone equalizer
when the speech processor is activated.
Available Values: 1 - 10
Default Setting: 2
Description: Activates when the speech processor is
“ON” and sets the width
(
“Q”
)
for the low
range of the 3 band parametric microphone
equalizer between “
1
” and “
10
”.
133 P-PRMTRC EQ2 FREQ
Function: Selects the center frequency for the middle
range of the 3 band parametric microphone
equalizer when the speech processor is acti-
vated.
Available Values: 700 - 1500
(
Hz
)
/OFF
(
100Hz/step
)
Default Setting: 800
Description: Selects the center frequency for the middle
range of the 3 band parametric microphone
equalizer between “
700 Hz
and
1500
Hz
” when the speech processor is activated.
134 P-PRMTRC EQ2 LEVEL
Function: Sets the gain for the middle range of the 3
band parametric microphone equalizer when
the speech processor is activated.
Available Values: −20 - 0 - 10
(
dB
)
Default Setting: 0
Description: Selects the gain setting for the middle range
of the 3 band parametric microphone equal-
izer between “−
20 dB
and
+10 dB
when the speech processor is activated.
135 P-PRMTRC EQ2 BWTH
Function: Sets the width
(
“Q”
)
for the middle range of
the 3 band parametric microphone equalizer
when the speech processor is activated.
Available Values: 1 - 10
Default Setting: 1
Description: Activates when the speech processor is
“ON”, and selects the width
(
“Q”
)
setting
for the middle range of the 3 band paramet-
ric microphone equalizer between “
1
and
10
”.
136 P-PRMTRC EQ3 FREQ
Function: Sets the center frequency for the high range of
the 3 band parametric microphone equalizer
when the speech processor is activated.
Available Values: 1500 - 3200
(
Hz
)
/OFF
(
100Hz/step
)
Default Setting: 2100
Description: Activates when the speech processor is
“ON”, and selects the center frequency
setting for the high range of the 3 band
parametric microphone equalizer between
1500 Hz
” and “
3200 Hz
”.
137 P-PRMTRC EQ3 LEVEL
Function: Sets the gain for the high range of the 3 band
parametric microphone equalizer when the
speech processor is activated.
Available Values: −20 - 0 - 10
(
dB
)
Default Setting: 0
Description: Activates when the speech processor is
“ON”, and selects the gain setting for the
high range of the 3 band parametric micro-
phone equalizer between “−
20 dB
and
+10 dB
”.
138 P-PRMTRC EQ3 BWTH
Function: Sets the width
(
“Q”
)
for the high range of the
3 band parametric microphone equalizer when
the speech processor is activated.
Available Values: 1 - 10
Default Setting: 1
Description: Activates when the speech processor is
“ON”, and sets the width
(
‘Q”
)
for the high
range of the 3 band parametric microphone
equalizer between “
1
” and “
10
”.
139 HF TX MAX POWER
Function: Sets the transmit RF power output of the HF
band.
Available Values: 5 - 100
Default Setting: 100
140 50M TX MAX POWER
Function: Sets the transmit RF power output of the 50
MHz band.
Available Values: 5 - 100
Default Setting: 100
141 144 TX MAX POWER
Function: Sets the transmit RF power output of the 144
MHz band.
Available Values: 5 - 50
Default Setting: 50
142 430M TX MAX POWER
Function: Sets the transmit RF power output of the 430
MHz band.
Available Values: 5 - 50
Default Setting: 50
138


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yaesu FT-991A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yaesu FT-991A in the language / languages: English as an attachment in your email.

The manual is 36,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info