Page 135FT-
991
OperaTing Manual
Menu MODe
118 SCP SPAN FREQ
Function: Sets the bandwidth of the spectrum scope
sweeping.
Available Values: 50/100/200/500/1000
(
kHz
)
Default Setting: 100kHz
Description: Sets the bandwidth
(
SPAN
)
of the spectrum
scope.
119 SPECTRUM COLOR
Function: Selects the color of the Spectrum Scope dis-
play.
Available Values: BLUE/GRAY/GREEN/ORANGE/
PURPLE/RED/SKY BLUE
Default Setting: BLUE
120 WATER FALL COLOR
Function: Selects the color of the Water Fall display.
Available Values: BLUE/GRAY/GREEN/ORANGE/
PURPLE/RED/SKY BLUE/MULTI
Default Setting: MULTI
121 PRMTRC EQ1 FREQ
Function: Sets the center frequency of the low range for
the 3 band parametric microphone equalizer.
Available Values: 100 - 700
(
Hz
)
/OFF
(
100Hz/step
)
Default Setting: OFF
Description: Selects the center frequency setting of the
low range of the 3 band parametric micro-
phone equalizer between
100 Hz
and
700 Hz
”.
122 PRMTRC EQ1 LEVEL
Function: Sets the gain for the low range of the 3 band
parametric microphone equalizer.
Available Values: −20 - 0 - 10
(
dB
)
Default Setting: 5
Description: Adjusts the gain for the low range of the 3
band parametric microphone equalizer be-
tween “−
20 dB
” and “
+10 dB
”.
123 PRMTRC EQ1 BWTH
Function: Sets the width variation
(
“Q”
)
for the low
range of the 3 band parametric microphone
equalizer.
Available Values: 1 - 10
Default Setting: 10
Description: Selects the value of the width
(
Q
)
for the
low range for the 3 band parametric micro-
phone equalizer between “
1
” and “
10
”.
124 PRMTRC EQ2 FREQ
Function: Sets the center frequency for the middle range
of the 3 band parametric microphone equal-
izer.
Available Values: 700 - 1500
(
Hz
)
/OFF
(
100Hz/step
)
Default Setting: OFF
Description: Selects the center frequency setting for the
middle range of the 3 band parametric mi-
crophone equalizer between “
700 Hz
and
1500 Hz
”.
125 PRMTRC EQ2 LEVEL
Function: Sets the gain for the middle range of the 3
band parametric microphone equalizer.
Available Values: −20 - 0 - 10
(
dB
)
Default Setting: 5
Description: Selects the gain setting for the middle range
of the 3 band parametric microphone equal-
izer between “−
20 dB
” and “
+10 dB
”.
126 PRMTRC EQ2 BWTH
Function: Sets the width variation
(
“Q”
)
for the middle
range of the 3 band parametric microphone
equalizer.
Available Values: 1 - 10
Default Setting: 10
Description: Selects the width
(
“Q”
)
for the middle
range of the 3 band parametric microphone
equalizer between “
1
” and “
10
”.
127 PRMTRC EQ3 FREQ
Function: Sets the center frequency for the high range of
the 3 band parametric microphone equalizer.
Available Values: 1500 - 3200
(
Hz
)
/OFF
(
100Hz/step
)
Default Setting: OFF
Description: Selects the center frequency setting for the
high range of the 3 band parametric micro-
phone equalizer between “
1500 Hz
and
3200 Hz
”.
128 PRMTRC EQ3 LEVEL
Function: Sets the gain for the high range of the 3 band
parametric microphone equalizer.
Available Values: −20 - 0 - 10
(
dB
)
Default Setting: 5
Description: Selects the gain setting for the high range
of the 3 band parametric microphone equal-
izer between “−
20 dB
” and “
+10 dB
”.
129 PRMTRC EQ3 BWTH
Function: Selects the width setting
(
“Q”
)
for the high
range of the 3 band parametric microphone
equalizer.
Available Values: 1 - 10
Default Setting: 10
Description: Selects the width
(
“Q”
)
setting for the high
range of the 3 band parametric microphone
equalizer between “
1
” and “
10
”.
130 P-PRMTRC EQ1 FREQ
Function: Sets the center frequency of the low range for
the 3 band parametric microphone equalizer
when the speech processor is activated.
Available Values: 100 - 700
(
Hz
)
/OFF
(
100Hz/step
)
Default Setting: 200
Description: Activates when the speech processor is
“ON”. Adjusts the center frequency for the
low range of the 3 band parametric micro-
phone equalizer between
100 Hz
and
700 Hz
”.
137


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yaesu FT-991A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yaesu FT-991A in the language / languages: English as an attachment in your email.

The manual is 36,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info