Page 130 FT-
991
OperaTing Manual
Menu MODe
060 PC KEYING
Function: Sets the
RTTY/DATA
jack for keying.
Available Values: OFF/DAKY/RTS/DTR
Default Setting: OFF
Description:
OFF: Disables keying from DATA PTT
(
pin 3
)
of the
RTTY/DATA
jack.
DAKY: Controls the transmit from the
RTTY/
DATA
jack
(
pin 3
)
on the rear panel.
RTS: Controls the transmit from the USB vir-
tual COM/RTS ports.
DTR: Controls the transmit from the USB vir-
tual COM/DTR ports.
061 QSK DELAY TIME
Function: Sets the time delay before transmitting the
keying signal.
Available Values: 15/20/25/30msec
Default Setting: 15msec
Description:
The delay time in QSK mode before transmit-
ting the CW signal may be set in 5 msec steps.
062 DATA MODE
Function: Selects the operating scheme in DATA mode.
Available Values: PSK/OTHERS
Default Setting: PSK
Description: Selects the operating scheme
(
PSK or
OTHERS
)
in DATA mode.
063 PSK TONE
Function: Set the PSK tone.
Available Values: 1000/1500/2000Hz
Default Setting: 1000Hz
Description: Selects the PSK tone frequency.
064 OTHER DISP
(
SSB
)
Function: Sets the displayed frequency offset in DATA
mode.
Available Values: −3000 - 0 - 3000Hz
(
10Hz/step
)
Default: 0Hz
Description: Sets the displayed frequency offset in
DATA mode. The frequency can be set in
steps of 10 Hz.
065 OTHER SHIFT
(
SSB
)
Function: Sets the carrier point in DATA mode.
Available Values: −3000 - 0 - 3000Hz
(
10Hz/step
)
Default: 0Hz
Description: Sets the carrier point in DATA mode. The
frequency can be set in steps of 10 Hz.
066 DATA LCUT FREQ
Function: Sets the low-frequency cutoff audio filter in
DATA mode.
Available Values: OFF/100Hz - 1000Hz
(
50Hz/step
)
Default Setting: 300Hz
Description: This is the low-frequency cutoff audio lter
in DATA mode.
The cutoff frequency can be set at 50 Hz
increments between 100 Hz and 1000 Hz.
067 DATA LCUT SLOPE
Function: Sets the slope of the low-frequency cutoff au-
dio lter in DATA mode.
Available Values: 6dB/oct / 18dB/oct
Default Setting: 18dB/oct
Description: Selects the slope setting of the low-frequen-
cy cutoff audio lter in DATA mode.
068 DATA HCUT FREQ
Function: Sets the high-frequency cutoff audio lter in
DATA mode.
Available Values: OFF/700Hz - 4000Hz
(
50Hz/step
)
Default Setting: 3000Hz
Description: This is the high-frequency cutoff audio l-
ter in DATA mode.
The cutoff frequency can be set at 50 Hz
increments between 700 Hz and 4000 Hz.
069 DATA HCUT SLOPE
Function: Sets the slope of the high-frequency cutoff au-
dio lter in DATA mode.
Available Values: 6dB/oct / 18dB/oct
Default Setting: 18dB/oct
Description: Selects the slope setting of the high-fre-
quency cutoff audio lter in DATA mode.
070 DATA IN SELECT
Function: Selects the input jack for DATA mode.
Available Values: MIC/REAR
Default Setting: REAR
Description: Selects the input jack to be used in DATA
mode.
MIC: Inputs signals from the
MIC
jack on the
front panel.
REAR: Inputs signals from the
USB
jack or
RTTY/DATA
jack on the rear panel.
071 DATA PTT SELECT
Function: Sets the PTT control during the sending/re-
ceiving of data.
Available Values: DAKY/RTS/DTR
Default Setting: DAKY
Description: Selects the PTT control method during the
sending/receiving of data.
DAKY: Controls the transmit from the
RTTY/
DATA
jack
(
pin 3
)
on the rear panel.
DTR: Controls the transmit from the USB vir-
tual COM/DTR ports.
RTS: Controls the transmit from the USB vir-
tual COM/RTS ports.
132


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yaesu FT-991A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yaesu FT-991A in the language / languages: English as an attachment in your email.

The manual is 36,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info