36023
29
Zoom out
Zoom in
Previous page
1/76
Next page
Page 27FT-897D OPERATING MANUAL
DSP CW PEAKING FILTER
In the CW mode, pressing the
[
C
](
DBF
)
key in Multi Func-
tion Row “p”
[
DNR, DNF, DBF
]
activates a narrow-band-
width peaking filter, which may be ideal for use under very
crowded conditions. The DSP CW Peaking Filter also is
especially helpful under VHF/UHF weak-signal situations.
The center frequency of the DSP CW Peaking Filter is auto-
matically aligned to be centered on the response you have
selected via the Menu Mode in item No-027
[
CW PITCH
]
.
See page 57 for details.
To change the bandwidth of the DSP CW Peaking Filter:
1. Press and hold in the
[
C
](
DBF
)
key for one second on
the CW mode. This instantly activates Menu Mode No-
045 [DSP BPF WIDTH
]
, which allows selection of the
bandwidth of the DSP CW Peaking Filter.
2. Rotate the DIAL to select the desired bandwidth. The
available values are 60 Hz, 120 Hz, and 240 Hz (default
value: 240 Hz).
3. When you have made your selection, press and hold in
the
[
F
]
key for one second to save the new setting and
return to normal operation.
DSP NOISE REDUCTION
(
NR
)
The Noise Reduction feature of the DSP system may be used
to enhance signal-to-noise ratio on weak signals.
1. Press the
[
DSP
]
key momentarily. This instantly acti-
vates Multi Function Row “p”
[
DNR, DNF, DBF
]
.
2. Press the
[
A
](
DNR
)
key to activate the DSP Noise Re-
duction feature. “Parentheses” will appear on the both
sides of the “DNR” indication, and the “DSP” will ap-
pear at the center top on the display.
3. Now press and hold in the
[
A
](
DNR
)
key for one sec-
ond. This instantly activates Menu Mode No-049
[
DSP
NR LEVEL
]
, which allows adjustment of the DSP Noise
Reduction level.
4. Rotate the DIAL to find the point where best signal-to-
noise ratio is obtained under the current noise condi-
tions.
5. Press and hold in the
[
F
]
key for one second to save the
new setting and exit to normal operation.
6. To turn off the DSP Noise Reduction feature, press the
[
A
](
DNR
)
key again.
If noise is present at a level which causes indi-
cation on the S-meter, the performance of the
Noise Reduction filter may be enhanced by ro-
tating the SQL/RF (RF Gain) control in a counter-clock-
wise direction so as to set the (fixed) S-meter reading at
the same level as the noise peaks. This adjustment raises
the AGC threshold of the receiver.
DSP NOTCH FILTER
The DSP system’s Notch Filter may be helpful in removing
one or more offending carrier or heterodyne signals from
the audio passband.
1. Press the
[
DSP
]
key momentarily. This instantly acti-
vates Multi Function Row “p”
[
DNR, DNF, DBF
]
.
2. Press the
[
B
](
DNF
)
key to activate the Notch Filter. “Pa-
rentheses” will appear on the both sides of the “DNF
indication, and the “DSP” will appear at the center top
on the display. You will notice that the audio level of the
carrier signal is now being reduced.
3. Press the
[
B
](
DNF
)
key once more to turn the Notch
Filter off.
Do not activate this filter in the CW mode, as
incoming CW signals will be notched out of the
audio passband!
RECEIVER ACCESSORIES
60 Hz
120 Hz
240 Hz
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yaesu ft-897D at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yaesu ft-897D in the language / languages: English as an attachment in your email.

The manual is 3,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info