The charge process
The LBC 500XTR standards has a 4-stage process to charge en maintain the
battery the correct way. The charger will always start in the first stage, the bulk
phase (LED red). This first stage has a minimum time length of 30 minutes, so
also when a full battery is connected. In the second stage, the equalize stage
(LED yellow) the will be charged to 100%. The length of the charging time
depends on the battery quality, battery capacity, depth of discharge and the
current draw of any present users. Furthermore any faults could delay the
process.
If the charge process is finished, the charger will switch automatically to the float
charge (LED green) keeping the battery under continues maintenance. If the
charger is in this stage for 24 hours at a minor current, the charger will go to its
‘jogging’ mode. This is a special charge stage for batteries that aren’t used for a
longer period of time, for instance during a winter break.
Important
The charging process may only be stopped when it is finished, so when the
green
charging process LED lights or flashes. If the charging process is
interrupted before it is completed, the battery loses its charge and its acid
balance.
When disconnecting the battery, at interruption of the mains voltage or when the
charger is put in its stand-by function, the current charge process will stop.
When a battery is re-connected, the mains voltage is present again or when the
charger is re-activated from its stand-by function, in all cases a new charge
process will start.
When a problem is detected at the start or during the charge process, the
‘power’ LED will light up red. Advice the Trouble Shooter for the needed actions.
LiFePO4 setting
If the charger is set on the LiFePO4 setting, then the charger will follow a special
charging program for this kind of battery, including a BMS auto start system. If
the charger doesn’t detect a battery, it will send a pulse every 20 seconds to
start up a potentially present BMS. During these pulses the 4 setting LED’s will
light as indication.
Turning the charger on/off
With the push button ‘power/mode’ button on the front side, the charger can be
turned off. Push and hold this button for 2 seconds, the charger will turn in its
stand-by function. In this stand-by mode the “Power” LED will flash two times
every 10 seconds. During this period the charger is in its power save mode.
To re-activate the charger, the ‘power/mode’ button must be pushed shortly. The
‘power’ LED will turn to green again. If a battery is present, a new charge
process will start directly.
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Xenteq LBC 524-10XTR at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Xenteq LBC 524-10XTR in the language / languages: English, German, Dutch as an attachment in your email.

The manual is 0,99 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info