Maintenance Cleaning
1. Completely empty the tank of fuel. Ensure the fuel tap/lever (23) is in the
OFF position.
2. Compress the two wire arms of the hose clamp on the outlet hose at the
fuel tap/lever (23) and slide the clamp back from the end of the hose by
approx. 25mm (Fig AF). Slide the fuel hose o the outlet of the fuel tap/
lever (23) in an anti clockwise direction.
3. Loosen the lock nut locking the fuel tap/lever (23) on to the tank
(Fig AG) in an anti clockwise direction. Unscrew the tap from the tank,
in an anti clockwise direction, and withdraw the tap from the tank.
Be careful not to lose the small seal on the thread of the tap.
4. Unscrew the fuel tap extension lter (Fig. AH).
NOTE: This lter can be cleaned in petrol to remove any build-up of dirt
on the outside of the lter, or the lter can be replaced. Do not operate
the generator without this lter in place. To replace the lter after
cleaning, or with a new lter, simply screw the lter into the inlet side of
the tap.
5. Ensuring the small seal is tted to the tap thread, screw the tap back into
the tank by a FULL 3 – 4 turns. Orientate the fuel tap/ lever (23) so the
outlet of the tap is towards the rear of the tank, and the tap control is to
the right hand side of the tank. Holding the tap rm, tighten the lock nut
(Fig AE), ensuring the seal is clamped between the lock nut and the tank.
6. Ret the fuel hose to the outlet of the tap and with the wire arms
compressed, slide the hose clamp up onto the connection of the hose
and the tap.
7. Rell the tank with fuel and ensure there are no leaks between the fuel
tap / lever (23) and the tank, and with the fuel tap turned on, ensure there
are no leaks where the fuel hose is tted to the outlet of the tap.
AG.AF. AH.
1. Keep your machine clean. The outside of the machine can be cleaned
using a damp soft cloth with a mild detergent if required. Never use water
to clean the generator as it may cause damage to internal parts.
2. Some maintenance products and solvents may damage the plastic parts;
these include products containing benzene, trichloroethylene, chloride
and ammonia.
3. Use a vacuum to clean air inlet and outlet louvres of the alternator.
4. Take special care to keep the ventilation inlets/outlets free from
obstruction; cleaning with a soft brush followed by a compressed air jet
will usually be sucient to ensure acceptable internal cleanliness.
5. Wear eye protection when carrying out cleaning.
Your new Workzone® Titanium Inverter Generator will more than satisfy your
expectations.
It has been manufactured under stringent Workzone® Titanium Quality
Standards to meet superior performance criteria.
You will nd your new Inverter Generator easy and safe to operate, and, with
proper care, it will give you many years of dependable service.
CAUTION. Carefully read through this entire instruction manual before
using your new Workzone® Titanium Inverter Generator.
Take special care to heed the Cautions and Warnings.
Your Workzone® Titanium Inverter Generator has many features that will
make your job faster and easier. Safety, performance, and dependability
have been given top priority in the development of this Generator, making it
easy to maintain and operate.
Use only Workzone® Titanium replacement parts for your product.
Non-conforming parts or modications made to parts will void
your warranty.
Cleaning
Warranty
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Workzone EP2800i at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Workzone EP2800i in the language / languages: English as an attachment in your email.

The manual is 1,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info