SETTINGS
6 720 802 172 (2012/06) 17
Room temperature:
Set the room temperature that should apply in the event of enabled
external control.
Value > 0 °C enables the function.
The highest temperature is used if temperature changes have been set
for a certain circuit at several external inputs.
Other functions:
13.8 GENERAL
Among other things, settings for date and time are available here.
> Room sensor settings (room controller)
>> Show outdoor temperature in room sensor (room controller)
> Set date
> Set time
Check and change, if necessary, date and time. These are used by the
control unit to manage the different clock settings, e.g., holiday and
room temperature program.
> Summer/winter time
Select if there should be automatic change over between summer and
winter time or not (dates according to EU standard).
> Display contrast
If necessary, change the background light of the control panel.
> Language
Change language, if desired.
13.9 ALARMS
The different alarms that can occur are described in (Chapter 14).
Under Alarms there is:
Information log
Delete information log
Alarm log
Delete alarm log
Alarm indication
> Information log
The information log shows information from the heat pump. The
information log symbol is displayed in the control panel initial menu
when there is active information.
> Delete information log
The information log is deleted here.
> Alarm log
The alarm log shows the alarms and warnings that have occurred. Alarm
category ( Chapter 14.5) is displayed in the top left corner of the
display. If the alarm is active, the alarm symbol (Chapter 11.3) is
displayed both in the alarm log and the initial menu of the control panel.
> Delete alarm log
The alarm log is deleted here.
> Alarm indication
Settings for alarm buzzer and status lamp are made here.
>> Alarm buzzer signal
>>> Interval
Set the length of the alarm interval.
The alarm buzzer sounds for one second and is silent during the rest
of the interval. The setting applies to all alarm buzzers.
>>> Blocking time
Set the times between which alarms buzzers should not be allowed to
produce an acoustic signal.
>> Alarm indication control unit
>>> Block alarm buzzer
The setting applies only to the control unit's alarm buzzer.
>> Alarm indication room sensor (room controller)
>>> Block alarm indicator lamp
The setting applies to all room controllers.
Factory setting No (0.0 °C)
Lowest value 10.0 °C
Highest value 35.0 °C
Table 33 Room temperature
Factory setting No
Alternative Yes/No
Table 34 Functions
Factory setting No
Alternative Yes/No
Table 35 Show outdoor temperature in room controller
Factory setting
Format yyyy-mm-dd
Table 36 Date
Factory setting
Format hh:mm:ss
Table 37 Time
Factory setting Automatic
Alternative Manual/Automatic
Table 38 Summer/winter time.
Factory setting 70%
Lowest value 0%
Highest value 100%
Table 39 Display contrast
Factory setting 2s
Lowest value 2s
Highest value 3600s (60min)
Table 40 Interval
Factory setting Off
Start time 0:00 - 23:45
Stop time 0:00 - 23:45
Table 41 Blocking time
Factory setting No
Alternative No/Yes
Table 42 Block alarm buzzer
Factory setting Yes
Alternative No/Yes
Table 43 Block indicator lamp
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Worcester Greenstore Ground Source at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Worcester Greenstore Ground Source in the language / languages: English as an attachment in your email.

The manual is 3.44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info