COMMISSIONING
GENERAL / USER INSTRUCTION
Before lighting the stove check with the installer that the installation
work and commissioning checks described above have been
carried out correctly and that the chimney has been swept clean,
is sound and free from any obstructions. As part of the stoves’
commissioning and handover the installer should have shown you
how to operate the stove correctly.
EXTRACTOR FAN
There must not be an extractor fan tted in the same room as the
stove as this can cause the stove to emit smoke and fumes into
the room.
AEROSOL SPRAYS
Do not use an aerosol spray on or near the stove when it is alight.
USE OF OPERATING TOOLS
Always use the operating tools provided when handling parts likely
to be hot when the stove is in use.
CHIMNEY FIRES
If the chimney is thoroughly and regularly swept, chimney res
should not occur. However, a chimney re can occur, due to sooting
and deposits of creosote in the chimney, if incorrect or wet wood is
used. If a chimney re does occur tightly close the doors and all the
air inlets on the stove. This should cause the chimney re to go out.
If the chimney re does not go out when the above action is taken
then the re brigade should be called immediately. Do not relight
the stove until the chimney and ueways have been cleaned and
inspected by an expert. The expert should check for the integrity of
the chimney and carry out any remedial work before the chimney
is put back into use.
APPROVED FUELS
Dry well seasoned and natural wood, (hardwood preferred) or
Defra exempt mineral smokeless fuels. Information on fuel types
can be found on www.gov.uk/smoke-control-area-rules
COMMISSIONING AND HANDOVER
Ensure all parts are tted in accordance with the instructions.
On completion of the installation allow a suitable period of time for
any re cement and mortar to dry out, before lighting the stove.
Once the stove is under re check all seals for soundness and
check that the ue is functioning correctly and that all products
of combustion are vented safely to atmosphere via the chimney
terminal.
On completion of the installation and commissioning ensure that
the operating instructions for the stove are left with the customer.
Ensure to advise the customer on the correct use of the appliance
and warn them to use only the recommended fuel for the stove.
Advise the user what to do should smoke or fumes be emitted from
the stove. The customer should be warned to use a reguard to BS
8423:2002 (Replaces BS 6539) in the presence of children, aged
and/or inrm persons.
These instructions together with those in the instruction booklet
cover the basic principles to ensure the satisfactory installation
of the stove, although detail may need slight modication to suit
particular local site conditions.
In all cases the installation must comply with current Building
Regulations, Local Authority Byelaws and other specications or
regulations as they affect the installation of the stove. It should be
noted that the Building Regulations requirements may be met by
adopting the relevant recommendations given in British Standards
BS 8303, BS EN 15287-1:2007 as an alternative means to achieve
an equivalent level of performance to that obtained following the
guidance given in Approved Document J.
Please note that it is a legal requirement under England and Wales
Building Regulations that the installation of the stove is either
carried out under Local Authority Building Control approval or is
installed by a Competent Person registered with a Government
approved Competent Persons Scheme.
CO ALARMS
Building regulations require that when ever a new or replacement
xed solid fuel or wood/ biomass appliance is installed in a dwelling
a carbon monoxide alarm must be tted in the same room as
the appliance. Further guidance on the installation of the carbon
monoxide alarm is available in BS EN 50292:2002 and from the
alarm manufacturer’s instructions. Provision of an alarm must
not be considered a substitute for either installing the appliance
correctly or ensuring regular servicing and maintenance of the
appliance and chimney system.
Your installer should have tted a CO alarm in the same room as
the appliance.
USE OF FIREGUARD
When using the stove in situations where children, aged and/or inrm
persons are present a reguard must be used to prevent accidental
contact with the stove. The reguard should be manufactured in
accordance with BS 8423:2002 (Replaces BS 6539).
HEALTH AND SAFETY PRECAUTIONS
Special care must be taken when installing the stove such that the
requirements of the Health and Safety at Work Act are met.
HANDLING
Adequate facilities must be available for loading, unloading and site
handling.
FIRE CEMENT
Some types of re cement are caustic and should not be allowed to
come into contact with the skin. In case of contact wash immediately
with plenty of water.
ASBESTOS
This stove contains no asbestos. If there is a possibility of disturbing
any asbestos in the course of installation then please seek specialist
guidance and use appropriate protective equipment.
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Worcester-Bosch Greenstyle Hanbury at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Worcester-Bosch Greenstyle Hanbury in the language / languages: English as an attachment in your email.

The manual is 9.09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info