Information for installer
6 720 648 748 (2014/03)
5.3 Settings in the service menu
Overview of settings
Adjustments
Adjustment
range1)
1) Values in bold = default setting
Description
A.1 CO | Fb | SC Controller (CO), room thermostat (Fb), zone
controller (SC)
H.C HC1 | HC2 |
HC3 | HC4
Heating circuit 1 to 42)
2) Only one Sense I can be assigned per heating circuit.
d.1 2 | 3 | 4 Control characteristics:
2: Fast (for high operating temperature and
small volume of heating water)
3: Average (for radiator heating system and
medium operating temperature)
4: Slow (for underfloor heating system and low
operating temperature)
E.1 – 3.0 ... 0.0
... + 3.0
If the room temperature displayed by the Sense I is
wrong, correct the deviation up to ±3 °C3).
3) Temporarily place an appropriate thermometer next to the Sense I for
comparative measurement. Keep away from heat sources for 1 hour.
P.1 4 | 5 Flow temperature control (4) or load
compensation (5)
L.1 1 | 0 Optimised pump run: pump run time at flow
temperature control is maximally shortened. Must
be switched off with buffer tanks in the system.
C.1 C | F Unit of displayed temperatures °C (C) or °F (F)
S.1 nF.12.01 Software version4)
4) Turn the control knob to read off the whole value.
F.1 1 | 01: Factory settings after reset/power failure
0: System settings maintained after reset/power
failure
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Worcester-Bosch Greenstar Sense I at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Worcester-Bosch Greenstar Sense I in the language / languages: English as an attachment in your email.

The manual is 0.92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info