GENERAL NOTES
14 GREENSTAR HEATSLAVE II EXTERNAL 12/18, 18/25 & 25/32
6 720 805 212a (07.2013)
GENERAL
INFORMATION
GENERAL NOTES
To get the best from your boiler. please read these instructions carefully.
CENTRAL HEATING SYSTEMS
During the first few hours of operation of the central heating system, check that all radiators are
being heated at an even rate. If the top of a radiator is at a lower temperature than the bottom then it
should be vented by releasing air through the venting screw at the top of the radiator. Ask your
installer to show you how this is done. Repeated venting will reduce the quantity of water in the
system and this must be replenished for safe and satisfactory operation of the boiler.
When excessive venting or water leaks are found in the system you must contact a service engineer
to inspect the installation and rectify any fault.
Only use additives compatible with the boiler and system. Use of incompatible additives can cause
damage and will invalidate the boiler guarantee.
CONDENSATE DRAIN
This is a condensing boiler and the terminal will, at times give out a plume of water vapour. This is
quite normal.
The boiler also produces quantities of condensate which is discharged regularly via a pipe to drain.
This pipe must not be blocked or altered in any way.
CLEARANCES - SERVICE
Your installer will have provided adequate space around the boiler for safety and servicing access.
Do not restrict this space with the addition of cupboards, shelves etc. next to the boiler.
ROOM THERMOSTAT
A room temperature controller must be fitted to control the central heating. Refer to instructions
supplied with the thermostat for information on siting and setting.
THE R M OSTATIC R ADIATOR VALVES
It is recommended that this type of valve is fitted to all but one of the radiators (or at least those in
the sleeping accommodation). The remaining radiator, which must be where the room thermostat is
located, should be un-controlled and must be left open.
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Worcester-Bosch Greenstar Heatslave II External at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Worcester-Bosch Greenstar Heatslave II External in the language / languages: English as an attachment in your email.

The manual is 0.47 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info