Fault finding
Greenstar Danesmoor External 2022+ & External System 2022+ – 6 721 844 015 (2022/01)
7Fault finding
In the event that the appliance stops functioning or does not perform as expected, you can carry out a few simple checks. These
checks are some of the most common causes and are listed in the table below. Should the problem persist, then it will be necessary
to contact Worcester, Bosch Group.
Problem Cause Remedy
Desired room
temperature is not
reached
Thermostatic radiator valve(s) set too low Increase thermostatic radiator valve setting(s).
Temperature control for central heating flow on
boiler set too low
Increase central heating flow temperature
control setting
Low temperature setting on the room thermostat Increase settings on room thermostat
Air trapped in heating system (System model) Bleed radiators and re-pressurise the heating
system
Low system water pressure (System model) Re-pressurise the system, refer to page 8
Desired room
temperature is too
high
Thermostatic radiator valve(s) are set too high Turn down thermostatic radiator valves/room
thermostat
Room thermostat is set too high Reduce the thermostat setting
Reduce central heating temperature by turning
down the Central Heating control on boiler
Heating stays on for
too long
Clock is incorrectly set Check setting and adjust
Hot water
temperature too low
Temperature set too low on cylinder thermostat
control.
Check setting and adjust
Air trapped in heating system (System model) Bleed radiators and re-pressurise the heating
system
Low system water pressure (System model) Re-pressurise the system, refer to page 8
Hot water
temperature too high
Temperature set too high on cylinder thermostat
control.
Check setting and adjust
System pressure low Leak within the heating system Check system for obvious leaks.
Table 2 Fault finding
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Worcester-Bosch Greenstar Danesmoor External Regular - External System at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Worcester-Bosch Greenstar Danesmoor External Regular - External System in the language / languages: English as an attachment in your email.

The manual is 1.07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info